7 - ELECTRICAL INSTALLATION

GENERAL
The connection to the electrical net-
work must be carried out by qualified
personnel and must be according to
existing norms.
The appliance must be connected to
the mains checking that the voltage
corresponds to the value given in the
rating plate and that the electrical ca-
ble sections can withstand the load
specified on the plate.
The appliance can be connected di-
rectly to the mains placing an omni-
polar switch with minimum opening
between the contacts of 3 mm betwe-
en the appliance and the mains.
The power supply cable must not
touch the hot parts and must be posi-
tioned so that it does not exceed 75°C
at any point.
Once the appliance has been installed,
the switch must always be accessible.
If the power supply cable (not supplied
with the appliance) is damaged it must
be substituted by a suitable cable.
FEEDER CABLE SECTION
Type H05RR-F or H05VV-F
230 V~ 4080 W (17,7 A)
(**) Connection with wall box connection.
IMPORTANT: This double oven must be
connected to a suitable double pole con-
trol unit adjacent to the oven.
NO DIVERSITY CAN BE APPLIED TO
THIS CONTROL UNIT.
34
3 x 2,5 mm
(**)
2
IMPORTANT: The double oven must be
installed in accordance with the manu-
facturer's instructions.
Incorrect installation, for which the
manufacturer accepts no responsibili-
ty, may cause damage to persons, ani-
mals and things.
Before effecting any intervention on
the electrical parts of the appliance,
the connection to the network must be
interrupted.
The connection of the appliance to
earth is mandatory.
The manufacturer declines all respon-
sability for any inconvenience resul-
ting from the inobservance of this con-
dition.