Loose Parts Bag Contents; Minimum Clearances To Combustible Materials - Bryant 987MA Installation, Start-Up, Operating And Service And Maintenance Instructions

Modulating 4-way multipoise gas furnace series a
Table of Contents

Advertisement

WARNING
!
FIRE, INJURY OR DEATH HAZARD
Failure to follow this warning could result in personal
injury, death and/or property damage.
When the furnace is installed in a residential garage, the
burners and ignition sources must be located at least 18 in.
(457 mm) above the floor. The furnace must be located or
protected to avoid damage by vehicles. When the furnace is
installed in a public garage, airplane hangar, or other
building having a hazardous atmosphere, the furnace must
be installed in accordance with the NFPA 54/ANSI
Z223.1- -2009 or CAN/CSA B149.2- -2010. (See Fig. 5.)
Outlet Choke Plate (used with 40k BTUH furnaces, only)
POSITION
Front (Combustion air openings in furnace and in structure)
Required for service
All Sides of Supply Plenum
Top of Furnace
* Recommended
Table 1 – Loose Parts Bag Contents (Provided in blower compartment)
DESCRIPTION
Air Intake Pipe Flange
Vent Pipe Flange
Coupling Flange Gaskets
Sharp Tip Screws (Vent and Inlet Flanges)
Vent Pipe Coupling
Vent Pipe Coupling Clamps
Pressure Switch Tube
Drain Tube Elbow
Drain Extension Tube
Drain Tube Clamps
Drain Line Grommet
Gas Line Grommet
Gas Line Knockout Plug
Junction Box Cover
Junction Box Base
Green Ground Screw
Blunt Tip Screws (Junction Box)
Thermostat Wire Grommet
Table 2 – Minimum Clearances to Combustible Materials for All Units
Rear
Sides
Vent
WARNING
!
FIRE HAZARD
Failure to follow this warning could result in personal
injury, death and/or property damage.
Do not install the furnace on its back or hang furnace with
control compartment facing downward. Safety control
operation will be adversely affected. Never connect
return- -air ducts to the back of the furnace. (See Fig. 4.)
Location Relative to Cooling Equipment
The cooling coil must be installed parallel with, or on the
downstream side of the unit to avoid condensation in the heat
exchangers. When installed parallel with the furnace, dampers or
other flow control must prevent chilled air from entering the
furnace. If the dampers are manually operated, they must be
equipped with means to prevent operation of either unit unless the
damper is in the full- -heat or full- -cool position.
CLEARANCE
0 (0 mm)
1 in. (25 mm)
*24 in. (610 mm)
1 in. (25 mm)
0 (0 mm)
0 (0 mm)
1 in. (25 mm)
6
QUANTITY
1
1
2
10
1
2
1
1
1
1
2
1
1
1
1
1
1
3
1