Hull Drainage Systems; Transom Drain; Bilge Pumps - Four winns 338 Vista Owner's Manual

Hide thumbs Also See for 338 Vista:
Table of Contents

Advertisement

Figure K1: Layered Deck Hatch
Screen/Sun/Shade System
NOTICE
Be sure deck hatch (s) is secured while under-
way. Damage to the hatch may result.
K - 3

HULL DRAINAGE SYSTEMS

A. Transom Drain
A transom drain with plug is provided in the engine
compartment to allow water drainage. When boat is
out of the water, the boat and cradle should be
positioned so any bilge water accumula tion during dry
stor age will flow towards the tran som.
Be sure the drain plug is securely in place prior
to launching the boat. Upon ship ment of the
boat, the drain plug is usually taped to the
steering wheel.
B. Bilge Pumps
Forward and aft bilge pumps are provided in the
bottom of the hull to remove miscellaneous water
accumulations that might occur during normal boating
or weather conditions. The aft bilge pump is controlled
by the BILGE PUMP switch located on the port helm
switch panel. Refer to Section H for further information
regarding bilge pumps.
Ventilation and Drainage Systems - Section K
The bilge pumps are equipped with an automatic
switch to control pump operation. As the water level
rises, the automatic float switch will activate the pump.
Separate circuit breakers are provided on the battery
switch to supply power directly from the "SHIP SYS-
TEMS" battery to the forward and aft bilge pumps
regard less of battery selector switch position.
NOTICE
While at rest, any bilge water accumula tion
may flow forward. DO NOT allow bilge water
to accumulate. Damage to the engine or other
compo nents may result. Periodically operate
the bilge pump to remove bilge water
accumulation.
When leaving the boat unattended for long periods of
time or during excessive rain storms, it is a good idea
to check on the boat for excessive water accumula-
tion. Be sure the bilge pumps and automatic float
switches are operating properly. The operating time of
the bilge pumps will be limited to the battery capacity.
Periodically, clean the bilge pump strainers. DO NOT
allow dirt and debris to clog the bilge pump intakes.
Check operation of the bilge pump float switch often to
ensure movement of the switch is not restricted by
debris, portions of the hull, etc.
Wipe up any oil accumu lation in the bilge prior to
activa tion of the bilge pumps. Pumping oil over board
will pol lute the water, and is subject to fine.
After winterization of the fresh water systems, be sure
the bilge area, bilge pumps and associated hoses are
thoroughly dry. Damage to the hull, bilge pumps and
other equipment could occur if water is allowed to
freeze in the bilge. Refer to the manufacturers litera-
ture included in the owner's packet for additional
information.
C. Sump
A sump box is installed in the floor, just forward of the
aft cabin. See the 338 Vista
back of this manual. It is equipped with an automatic
float switch and will pump water overboard or into the
grey water tank (if available). Refer to Section J-2D
on using the shower and for additional information on
sump pump operation.
locator drawing at the
®
Owner's Manual Page 123

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents