Motor Nameplate
Branch
Volts/Hz/
Full Load Amps
Circuit
Phase
12.0 or Less
15A
115/60/1 14 (2)
12.1 - 16.0
20A
115/60/1 10 (5.5) 8 (8.4)
16.1 - 20.0
25A
115/60/1 10 (5.5) 8 (8.4)
12.0 or Less
15A
230/60/1 14 (2)
Notice: Values given are for Pump motor only. Do not put any other accessories on this circuit.
NOTICE: Determine circuit breaker rating from the table above.
Determine correct outlet required from illustration below.
JWP 1/2, 3/4 and 1 HP Models
with suffixes -2A2, -A2U and
-6A2, as well as JWP 1-1/2 HP
models with suffixes -2A4U and
-6A2 use 15-amp straight
outlet, above.
Dist. In Ft. (m) (Serv. To Motor)
0-100'
101-200'
201-300'
(0-30)
(31-60)
(61-90)
12 (3)
10 (5.5)
6 (14)
6 (14)
12 (3)
10 (5.5)
JWP 1-1/2 HP Models with
suffixes -2A2 and -A2U use
suffixes -2A1 and -6A1 use 20-
20-amp straight outlet, above.
amp twist-lock outlet, above.
Startup/Operation
Temp
Rating- ◦ C
hair or body parts and can cause drowning. Do not
block pump suction. Small children using pool
75
must ALWAYS have close adult supervision.
75
75
75
JWP Models with
8
(See Figure 9)
Hazardous suction. Can trap and tear
Valve Setting
Purpose/Flow
FILTER
Normal filtration and
vacuuming; water goes
through filter to pool.
RINSE
For initial startup cleaning
and sand bed leveling
after backwash; water goes
through filter to waste.
RECIRCULATE
Circulates pool water;
bypasses filter.
Valve Setting
Purpose/Flow
BACKWASH
Reverses flow for
cleaning; water
goes through filter
to waste.
CLOSED
Shuts off all flow to
filter and pool.
F
WINTERIZE
Leaves all valve ports
partially open for
winter storage.
Figure 8
737 0294
738 0294

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: