• Improper venting of this appliance can result in excessive levels of carbon
monoxide which can result in severe personal injury or death.
• Improper installation can cause nausea or asphyxiation, severe injury or death
DANGER
from carbon monoxide and flue gases poisoning. Improper installation will
void product warranty.
When installing the vent system, all applicable national and local codes must be
followed. If you install thimbles, fire stops or other protective devices and they
penetrate any combustible or noncombustible construction, be sure to follow all
CAUTION
applicable national and local codes.
The water heater must be vented in accordance with the section "Venting of Equipment" of the latest
edition of the National Fuel Gas Code: ANSI Z223.1/NFPA 54 in the United States and/or Section 7 of the
CAN/CSA B149.1 Natural Gas Installation Code in Canada, as well as applicable local building codes.
The manufacturer recommends the NovaVent line. However, the following are also UL listed
manufacturers: ProTech Systems Inc. (FasNSeal), Metal-Fab Inc., and Heat-Fab Inc. (Saf-T Vent).
General rules for venting water heaters are:
• Place the water heater as close as possible to the vent termination.
• The vent collar of the water heater must be fastened directly to an unobstructed vent pipe.
• Do not weld the vent pipe to the water heater's vent collar.
• Do not cut the vent collar of the unit.
• The vent must be easily removable from the top of the water heater for normal service and
inspection of the unit.
• The water heater vent must not be connected to any other gas appliance or vent stack.
• Avoid using an oversized vent pipe or using extremely long runs of the pipe.
• For rooftop venting, a rain cap or other form of termination that prevents rain water from
entering into the water heater must be installed.
• Do not common vent or connect any vent from other appliances to the water heater vent.
General rules for vent terminations:
• Avoid locating the water heater vent termination near any air intake devices. These fans can
pick up the exhaust flue products from the water heater and return them to the building. This
can create a health hazard.
• Locate the vent termination so that it cannot be blocked by any debris, at any time. Most codes
require that the termination must be at least 12 in. (305 mm) above grade, but the installer may
determine if it should be higher depending on the job site condition and applicable codes.
• A proper sidewall termination is recommended when the water heater is vented through a
sidewall.
• Regarding the clearances from the exhaust termination to the air inlet or opening, refer to the
next few pages.

VENTING INSTRUCTIONS

For indoor models
-General-
13