JVC HX-Z3 Service Manual page 24

Compact component system
Hide thumbs Also See for HX-Z3:
Table of Contents

Advertisement

HX-Z3
Electrical Performance
Measurement
Items
conditions
Adjustment of
Mode: Forward or
recording bias
reverse mode
current
Recording mode
(Reference
Test tape
Value)
: AC-514 to TYPE
and AC-225 to
TYPE
Measurement output
terminal
: Both recording and
headphone terminals
Adjustment of
Reference frequency
recording and
: 1kHz and 10kHz
playback
(REF.: -20dB)
frequency
Test tape
characteristics
: AC-514 to TYPE
Measurement input
terminal
: OSC IN
Reference Values for Electrical Function Confirmation Items
Measurement
Items
conditions
Forward or reverse
Recording
Test tape
bias
: TYPE
frequency
Measurement
terminal : BIAS TP on
P.C. board
Forward or reverse
Eraser
Recording mode
current
Test tape
(Reference
: AC-514 to TYPE
value)
and AC-225 to
TYPE
Measurement
terminal : Both of the
eraser head terminals
1-24
Measurement method
1 With the recording and playback
mechanism, load the test tapes (AC-514 to
TYPE
and AC-225 to TYPE
the mechanism to the recording and
pausing condition in advance.
2 After connecting 100
recorder head, measure the bias current
with a valve voltmeter at both of the
terminals.
3 After resetting the [PAUSE] mode, start
recording. At this time, adjust VR31 for Lch
and VR32 for Rch so that the recording
bias current values become 4.0
) and 4.20
1 With the recording and playback
mechanism, load the test tapes (AC-514 to
TYPE
), and set the mechanism to the
recording and pausing condition in
advance.
2 While repetitively inputting the reference
frequency signal of 1kHz and 10kHz from
OSC IN, record and playback the rape.
3 While recording and playback the test tape
in TYPE
for Rch so that the output deviation
between 1kHz and 10kHz becomes
-1dB
2dB.
Measurement method
1 While changing over to and from BIAS 1
and 2, confirm that the frequency is
(AC-514)
changed.
2 With the recording and playback
mechanism, load the test tape.
(AC-514 to TYPE
mechanism to the recording and pausing
condition in advance.
3 Confirm that the BIAS TP frequency on the
P.C. board is 100kHz
1 While recording and playback mechanism,
load the test tapes (AC-514 to TYPE
and AC-225 to TYPE
mechanism to the recording and pausing
conditions in advance.
2 After setting to the recording conditions,
connect 1W in series to the eraser head on
the recording and playback mechanism
side, and measure the eraser current from
both of the eraser terminals.
), and set
in series to the
A (TYPE
A (TYPE
).
, adjust VR31 for Lch and VR32
), and set the
6kHz.
), and set the
Adjusting
Standard
positions
Values
VR31
AC-225
: 4.20
A
AC-514
: 4.0
A
Output
VR31
deviation
between
1kHz and
10kHz
: -1dB 2dB
Standard
Adjusting
Values
positions
100 kHz
6 kHz
TYPE
: 120 mA
TYPE
: 75 mA