Through Interface GbE0
The following procedure describes how to access the VCB's configuration directly
through the factory-configured interface.
To define a static IP address
Connect a communications cable between interface GbE0 and a computer.
1
This interface's IP configuration is:
IP address
Subnet mask
Gateway IP
address
To access the VCB unit from another computer initially, the two systems
2
must, at least temporarily, belong to the same network segment. That is,
the first three fields of the address and the subnet mask must be identical.
Write down the computer's current IP address and subnet mask so that you
can restore them later.
Change the remote computer's IP configuration temporarily to the same IP
address segment(10.0.10.x) and subnet mask listed in step 1.
Connect a network cable to any one of interfaces GbE1 - GbE3.
3
Through the VCB Web Management program, define a static IP address for
4
the connected NIC.
Restore your computer's original IP configuration.
5
Emblaze-VCON VCB5 User's Guide
10.0.10.10
255.255.0.0
0.0.0.0
Connect to GbE0.
2 Defining the VCB IP Configuration
7
Need help?
Do you have a question about the VCB5 and is the answer not in the manual?