8.4

Programming Chime Zones

You can program the keypad to emit a rapid, intermittent beep tone whenever designated zones are opened or only
when opened between certain hours. These zones are referred to as Chime Zones. Your installer can also program
your Chime Zones to beep upon closure.
1. Enter your [
2. Press the [9] button.
3. Press the [1] button to chime a zone. Then enter the number corresponding to the zone to be chimed, or use
the [ ] and [ ] buttons to scroll the list of zones. Press the [
appears on the screen. Press [
OR
Press the [2] button to set the time period a chimed zone will beep. Enter the time that the chimed zone(s) will
start beeping when opened (HH:MM). Enter the time that the chimed zone(s) will stop beeping when opened
(HH:MM).
4. Press [
CLEAR
8.5

Panic Alarms

Your system can be programmed to send an alarm to your monitoring station to request help from the police, a
medical facility, the fire department, or anyone you wish when you press a pre-determined combination of buttons.
To generate a panic alarm, simultaneously press and hold the button combinations displayed in Table 1 on page 13.
Your installer can program the alarm to be either silent or audible.
Emergency Panic
Auxiliary Panic
Fire Panic
8.6

Quick Function Buttons

You will only need to use the Quick Function Buttons upon your installer's or monitoring station's request. Only the
System Master Code or user access codes with the Master feature enabled will be able to access these functions.
To access the Quick Function Buttons:
1. Enter your [
2. Press the [0] button.
3. Press the:
[
STAY
[
FORCE
[
] button to answer the WinLoad software.
ARM
[
DISARM
9.0

Testing and Maintenance

9.1

Burglar Alarm Testing

Two people are needed to complete this test. One person will watch the LCD screen on the keypad while the other
person walks around the protected areas and opens the zones (i.e. opens the doors and windows that are
protected, walk in the path of the motion detectors, etc.). The LCD screen will display the opened zones, but if a
zone does not register, contact your installer.
9.2

Fire Alarm Testing

Do NOT use an open flame or burning materials to test your fire detection devices. Your installer will provide details
on the best way to test your system.
]
ACCESS CODE
ENTER
] to exit chime programming.
Panic Alarm Types
]
ACCESS CODE
] button to send a test report to the monitoring station.
] button to call the WinLoad software.
] button to cancel communication with the WinLoad software.
] to save.
Table 1: Panic Buttons
Buttons to be pressed and held
simultaneously
Press & hold the [1] and [3] buttons
Press & hold the [4] and [6] buttons
Press & hold the [7] and [9] buttons
] button to chime or unchime the zone that