4.
Remove the Release Lever, the Fusing Front Guide Plate and the Fusing Rear Guide
Plate. (2 screws)
(See "Figure 4-41 (p.195)")
5.
Remove the Thermistor (TH1) and the Thermostat (TS1). (3 screws)
(See "Figure 4-42 (p.195)")
6.
Remove the Fusing Roller and Pressure Roller. (screws, E-rings, C-rings)
(See "Figure 4-43 (p.195)")
Install the Fusing Roller and Pressure Roller so that they are not out
of alignment excessively.
Misalignment: ±3 mm maximum
3 mm max.
Figure 4-41. Fusing Guide Plate Removal
Disassembly and Assembly
3 mm max.
Pressure Roller
Fusing Roller
Printer Main Parts Disassembly and Assembly
Figure 4-42. Thermistor / Thermostat Removal
Figure 4-43. Heat Roller Removal