Item
Function
Capacity
Capacity
Dehumidifying capacity
Power cable
Communication cable
Power source
Running current
Unit model (color)
Fan
Heat exchanger
Dimension
(L×W×H)
Drainage pipe
Controller type
Refrigerant control
Noise level
Weight
Refrigerant
Pipe
Connecting method
Item
Function
Capacity
Capacity
Dehumidifying capacity
Power cable
Communication cable
Power source
Running current
Unit model (color)
Fan
Heat exchanger
Dimension
(L×W×H)
Drainage pipe
Controller type
Refrigerant control
Noise level
Weight
Refrigerant
Pipe
Connecting method
Model
10‐³×m³/h
N, V, Hz
Type × Number
Speed
Motor output power
Air-flows (H/M/L)
Type / Diameter
Total area
Temp. scope
External
Package
material, diameter
H/M/L
Net / Shipping
Type
Liquid
Gas
Model
10‐³×m³/h
N, V, Hz
Type × Number
Speed
Motor output power
Air-flows (H-M-L)
Type / Diameter
Total area
Temp. scope
External
Package
material, diameter
H/M/L
Net / Shipping
Type
Liquid
Gas
AS072FCBHA
Cooling
——
7000
BTU/h
2000
W
1.0
——
——
A / A
0.10
——
AS072FCBHA (white)
CROSS×1
——
1050/900/800
r/min
25
W
520/410/300
m³/h
mm
about 0.15
795×197×265
mm
880×315×330
mm
mm
——
——
36/33/29
dB(A)
7.6/10.6
kg / kg
——
mm
mm
——
AS122FCBHA
Cooling
——
12000
BTU/h
W
3500
1.6
——
——
A / A
0.15
AS122FCBHA (white)
——
CROSS×1
——
1250/1050/900
r/min
25
W
630/520/410
m³/h
mm
about 0.20
795×197×265
mm
mm
880×315×330
mm
——
——
dB(A)
39/37/30
7.6/10.6
kg / kg
——
mm
mm
——
AS092FCBHA
Heating
Cooling
9500
9000
2800
2600
/
1.0
2
3 × (1.0~1.5mm
2
2x(0.75~1.25mm
1, 220~230, 50
0.10
0.10
AS092FCBHA (white)
1250/1050/900
600/500/410
TP2M / 6.35×0.7
cooling: 6~7 / heating: 43~60
795×197×265
880×315×330
PVC, 11.4/16.4
Phone type infrared
Capillary tube
R407C
6.35
12.7
Flared
AS142FCBHA
Heating
Cooling
15000
14000
4500
4000
/
2.0
2
3 × 0.75mm
2
2x(0.75~1.25mm
1, 220~230, 50
0.15
0.15
AS142FCBHA (white)
1250/1050/900
640/570/450
TP2M / 6.35×0.7
cooling: 6~7 / heating: 43~60
928×197×265
1025×309×330
PVC, 11.4/16.4
Phone type infrared
Capillary tube
R407C
6.35
12.7
Flared
Heating
10000
3200
/
)
)
0.10
CROSS×1
25
about 0.15
37/35/30
7.6/10.6
Heating
17000
5000
/
)
0.15
CROSS×1
25
about 0.20
44/41/38
11/14