Protective Functions - Orientalmotor FE100 Operating Manual

Table of Contents

Advertisement

Functions
External input signals
External output signals
Speed display
Remote/local switching
("RUN/STOP", "FWD/REV")
Carrier frequency switching
Sink/source switching
Frequency/rpm switching
Speed display switching
based on gear ratio
∗ This is not the actual speed of the motor shaft.

Protective functions

When any of the protective functions has been actuated, the inverter will stop the
motor via the base blocking function.
The inverter's protective functions cover the following abnormalities and errors:
overcurrent, overheated circuit, overvoltage, low voltage, overheated motor, circuit
error, overload (150% of the rated output current for 1 minute), setting error, ground
fault
Weight
FE100A, FE100C, FE100S
FE200A, FE200C, FE200S
Photocoupler input
RUN/STOP, FWD/REV, ALARM RESET
Open-collector output
RUNNING, ALARM
Set speed
of the motor is displayed.
Switching between operation by the
RUN/STAND-BY switch or operation using external
input signals (factory setting: local)
Change the default setting if leak current from the
inverter-motor cable must be reduced.
(factory setting: 15 kHz).
Switching between sink input using 0 V common or
source input using 24 V common.
(factory setting: sink)
Either the set frequency or speed can be shown on
the speed display (factory setting: frequency).
The set speed shown on the speed display can be
switched to a desired speed matching the gear ratio.
Up to 96 speeds can be set using two rotary
switches (factory-set gear ratio: 1:1).
0.4 kg (0.88 lb.)
0.5 kg (1.1 lb.)
11 Appendix
– 61 –