Operating The Motor - Orientalmotor FE100 Operating Manual

Table of Contents

Advertisement

7.3 Operating the motor

To operate the motor, all you need is to turn on the inverter power, set the
RUN/STAND-BY switch to the RUN side, and then adjust the speed potentiometer
to a desired setting. Turning the speed potentiometer clockwise will increase the
motor speed.
The acceleration time and deceleration time are set to their defaults (0.1 second).
1
Turn on the inverter power.
3
Adjust the speed using
the speed potentiometer.
Stopping the motor:
Changing the direction:
Changing the acceleration/deceleration time:
Low
speed
Set the RUN/STAND-BY switch to the STAND-BY
side.
Stop the motor, remove the front panel, and then tilt
the direction selector switch to the opposite side.
When the switch is set to the FWD side, the motor
shaft will turn clockwise. When the switch is set to
the REV side, the motor shaft will turn
counterclockwise. The direction indicates the
rotating direction of the motor shaft as viewed from
the motor output shaft. Depending on the gear ratio
of the gearhead, the direction of the gear output shaft
may become opposite to the motor direction.
The default is 0.1 second for both. To change the
default acceleration/deceleration time, refer to 8.1
"Setting the acceleration time and deceleration time"
on p.44.
High
speed
Direction selector switch
2
Set the RUN/STAND-BY
switch to the RUN side.
7 Operation
– 39 –