7.6 Timing chart

Motor direction
Counterclockwise
Switches at
RUN/STAND-BY
inverter front
Speed (frequency) setting
(RUN/STOP)
Input signals
(FWD/REV)
S1: Remote/local
DIP
switches
S2: Remote/local
Output signal
(RUNNING)
∗1 The DIP switches are enabled only when the motor is stopped.
If any of the DIP switches is changed while the motor is running, the new setting will take
effect after the motor stops.
∗2 When external DC voltage is connected to the inverter, either the speed set by the X3
terminal (EXTERNAL SPEED SETTING) or speed set by the inverter's speed
potentiometer, whichever is higher, will be given priority.
∗3 To switch the motor direction, stop the motor first, and then input a reversing signal.
Changing the motor direction instantaneously while the motor is running may damage the
gearhead or motor due to an impact load.
∗4 The direction indicates the rotating direction of the motor shaft as viewed from the motor
output shaft (FWD: clockwise, REV: counterclockwise). Depending on the gear ratio of the
gearhead, the direction of the gear output shaft may become opposite to the motor direction.
Clockwise
(FWD)
(REV)
RUN
FWD/REV
X0_C0
ON
OFF
X1_C0
ON
OFF
(RUN/STOP)
(FWD/REV)
Y0_C1
ON
OFF
RUN
RUN
FWD
REV
Stopped
FWD
Local
Local
Speed potentiometer on the inverter
External speed input via external DC voltage
7 Operation
STAND-BY
FWD
Running
Running
REV
Remote
Remote
– 43 –