6.3 Connecting the I/O signal terminals

Connect the motor to the I/O signal terminals if you want to operate the motor via
external input signals. Connect the I/O signal cables to the I/O signal terminals (TB2,
TB3). Keep the lengths of cables to 10 m (32.8 ft.) or less and wire them away from
the power lines. To allow speed setting via external signals, use a twisted-pair
shielded cable, shielded cable, etc.
Strip the signal cable by 5.5 mm (0.22 in.) from the end.
Terminal thread size and applicable cable size
Terminal thread
size
M2
When using crimp terminals, use the following products.
Manufacturer
PHOENIX CONTACT
GmbH & Co. KG
– 32 –
5.5 mm (0.22 in.)
Tightening torque
0.22 to 0.25 N·m
(31 to 35 oz-in)
Part number
AI0.5-6
AI0.75-6
Applicable cable size
AWG20, 18
2
(0.5 to 0.75 mm
)
Applicable wire size
2
AWG20 (0.5 mm
2
AWG18 (0.75 mm
Recommended
size
AWG18
2
(0.75 mm