Texecom Premier 48-W Quick Start Manual page 8

Hide thumbs Also See for Premier 48-W:
Table of Contents

Advertisement

Premier 48-W Quick Start Guide
14: Enable 2 wire smoke
Panel Output 1 can be used for connecting up to 10, 12V 2-Wire
smoke detectors.
15: Ricochet™ Network LED's
Green LED = Data received by the expander from the panel Red LED
= Data transmitted by the expander to the panel. (The flash rate
depends on the mode and RF activity)
16: Options Switch
Use to select the receiver functionality.
Switch 1 OFF =not used on Premier 48-W.
Switch 2 OFF = Premier 48-W RICOCHET™Mode
ON = Not Used
Switch 3 ON = Impaq Contact-W Wired Input 2 will report as Tamper
(default)
OFF = input 2 will report as an Alarm.
Switch 4 OFF Walk test (see page 12)
17: RICOCHET™ Eng keypad connection
An engineer's keypad (Premier LCD keypad and interface lead) can
be temporarily plugged onto this connector to allow system
programming and testing. Set the keypad address switches to all
ON.
18: RICOCHET™Firmware Flash Port
Connections for flasher interface to update RICOCHET™ receiver
firmware.
19: Commission Mode Jumper
Fit when learning and placing devices, remove once complete.
20: Antenna
RF antenna
21: RF LED's
Left = RED Transmit, Middle = GREEN Receive, Right = RED
Wireless Network Tick.
22: Plug-on Communicator Connections
This socket provides connection for Premier COM300/COM2400
plug-on communicators via the lead provided.
23: Ricochet™ Comm. Port Connection
Serial communications port for connecting to a PC via PC Com/USB
Com or Com IP for use with RICOCHET™ Monitor Software.
24: Cover Tamper Disable
Disables the lid tamper
25: Cover Tamper
Provides tamper protection for the control panel.
26: Heartbeat LED/Power Light
Flashes steadily to indicate that the control panel is functioning
correctly. If the light is ON or OFF all the time, then there could be a
problem.
27: Flash Programming Port
For upgrading the panel firmware.
28: Expansion
The Expansion Port can be used for connecting a 60XiD Zone
Expander or an AV Module.
29: Current Reading Pads
To calculate the current draw of the control panel, measure the
voltage across the two pads and multiply by 10 i.e. Reading = 34mV
(x10) = 340mV = 340mA.
30: Communication Ports
Com Port 1 is a serial communications port and can be used for
connecting a PC running Wintex or any supported serial device to the
control panel.
8
Com Port 2 is a serial communications port and can be used for
connecting a PC running Wintex or any supported serial device to the
control panel.
31: Battery Kick-start Button
When powering up the panel without AC Mains present, this button
must be pressed in order to connect the battery. If AC Mains is
present this button does not need to be pressed.
32: Engineers Keypad
A portable Engineers keypad can be plugged on here to allow easier
access for programming and testing.
When using a keypad as an Engineers keypad, the
address must be set to '10'. The keypad zones and lid
tamper are not monitored.