Premier 48-W Quick Start Guide
2. System Overview
System Architecture
0 to 48 Zones
32 W ireles s Devic e s lots
Wireles s R eceiver
8 P rogrammable
100mA Outputs
P remier
2 P rogrammable
Outputs
(2 x 500m
A )
S peaker Output
B ell/S trobe Outputs
(C om300 or C om2400)
B ell Tamper Input
Auxiliary Tamper Input
PC and
PC /US B -C om
for
Local Upload/Download
PC /USB -C om
Control Panel Features
Premier 48-W
•
32 wireless device Ricochet™ enabled receiver onboard
•
Expandable to 48 zones via keypads and zone expanders
•
1 x 4-wire data network (standard 7/0.2 alarm cable)
•
Up to 4 keypads and 3 zone expanders
•
Up to 2 output modules
•
4 independent areas each with 3 part arms
•
4 area arm suites
•
25 programmable User codes
•
500 Event Log (time & date stamped)
•
2 programmable panel outputs (2 x 500mA )
•
1.0 Amp power supply
•
32 Event Alarm Log
•
500 Event Mandatory Log
•
8 programmable digicom outputs (100mA each)
•
32 character zone text
•
Facility for Plug-on Digimodem (Com300/2400/)
•
Facility for Plug-on Paknet RP9 Radio-Pad
•
Facility for Plug-on GSM Module
•
Facility for Plug-on IP Module (ComIP/Chiron/WebWayOne/Emizon)
or any supported device
•
PC-Com/printer port
4
2 Zone
1Programmable
Inputs
100mA Output
32 Devic e
Premier
O mi
S erv ice
1
2
3
Omit
Reset
abc
def
4
5
6
ghi
jkl
mno
Chime
7
8
9
Part
pqrs
tuv
wxyz
Yes
0
No
Area
Menu
4 Wire Data Network 1
P remier LC D/LC DP
48-W
Plug on Digimodem
Plug on
R adio-Pad,
G S M Module
4 K eypads
2 Zone
1Programmable
Inputs
100mA Output
Power
Power
Info.
Info.
Ready
Ready
O mit
S erv ice
S peaker
1
2
3
Omit
Reset
abc
def
Output
4
5
6
ghi
jkl
mno
Chime
7
8
9
Part
pqrs
tuv
wxyz
Yes
0
No
Area
Menu
PC and Modem for
R emote Upload/Download
Modem
Alarm R eceiving
C entre
Power Supply Ratings
System Standby Times
Grade 2
12 Hours
The "Rated Power" of the control panel will depend on the size of the
standby battery, standby time and the installation grade:
When calculating the current consumption of the system you must
include the current taken by the control panel and all the devices that
it powers. If the total current exceeds the "Rated Output" for the
grade you are installing to then an additional power supply is
required.
Connecting AC Mains
The AC Mains supply is connected to a 3 way 'Euro Type' fused
terminal block, which is fitted with a 125mA fuse.
After connecting the AC Mains, fit the mains cover, this can be
found in the spares bag.
2 O utput Modules
16 Programmable
100mA Outputs
P remier OP 16
7 Ah Standby Battery
Max Power
Available from
control panel
600mA
All other wiring MUST be carried out before AC mains is
connected to the control panel.
To transformer
3 E xpanders
8 Zone Inputs
8 P rogrammable
100mA Outputs
S peaker Output
Auxiliary Input
P remier 8XP
Grade 2 –
Rating
580mA
L
E
N
INS531