Technical Specifications; Technical Specifications 3 X 400 V - OEM DC BWA-SS-7 Installation And Maintenance Instructions Manual

Dc inverter ground source heat pump - all in one
Table of Contents

Advertisement

57
IP 21
Refrigerant : R410A
Type ( DC BWA-SS SERIES )
Heating Capacity at 0/35 °C
Heating Power Input at 0/35 °C
Operational voltage
Starting current, compressor
Heating current, compressor
Operating current of electrical heater 9 kW
Output, brine pump
Output, HC pump
Connection brine o.d. Ø
Connection heating medium, o.d. ø
Water tank inlet/outlet, o.d. ø
Required ceiling height
Volume, water heater
Volume, spiral copper pipe
Max pressure in storage heater
Max pressure in spiral copper pipe volume
Refrigerant quantity (R410A)
Brine flow
Heating medium flow
Max pressure collector system
Operating temperature collector system
Max temp. (flow/return circuit)
Cut-out value pressostat HP
Difference pressostat HP
Cut-out value pressostat LP
Difference pressostat LP
Enclosure class
Noise of indoor unit
Net Weight / Gross Weight of indoor unit

Technical specifications

Technical specifications 3 x 400 V

( KW )
( KW )
(V)
(A)
(A)
(A)
(W)
(W)
(mm)
(mm)
(mm)
(mm)
(litres)
(litres)
(MPa)
(MPa)
(kg)
(m3/h)
(m3/h)
(bar)
(°C)
(°C)
(bar)
(bar)
(bar)
(bar)
dB(A)
(Kg)
9
12
9.98
11.85
2.45
2.925
400 V / 3 / 50 Hz
30
4.3
5.0
14X3
14X3
151
151
151
151
1980
200
200
12.20
12.20
0
6 .
0
2 .
1.45
1.70
1.75
2.0
1.5
2.05
-12 +20
68/55
40
IP 21
48
48
250/281
222/250
15
14.60
3.59
30
30
6.8
14X3
151
205
28
28
28
200
12.20
6 (
b
a
r)
5
2 (
5 .
b
a
r)
2.35
2.5
2.5
3
40
-7
0.5
+1
258/281
40
48

Advertisement