Control; General Information; Menus; Main Menu Information - OEM DC BWA-SS-7 Installation And Maintenance Instructions Manual

Dc inverter ground source heat pump - all in one
Table of Contents

Advertisement

Menu Navigation
The right-hand button on the control panel is used to open the desired menu.
The left-hand button is used to return to the previous menu.
The up and down buttons are used to navigate between the parameters of a menu.
A cursor (arrow) on the left-hand side of the display indicates which menu can be opened.
The up and down buttons are also used if you wish to increase or reduce a preset value.
Display of current operating mode
During normal operation, the following information will be displayed:
• Desired (preset) room temperature
• Date / time / timer
• Whether there is a heating demand or not. If there is, there will
also be symbols telling which heat source is working,
heat pump or auxiliary heater or both (see "Symbols").
• Which operating mode has been selected.
When display at the interface, press button Right for 5 seconds for locking the display (will show a symbol
of lock.) All buttons are not available after lock is active, until press button Right for 5 seconds to open the lock
if the lock is active and then power supply cut off, the lock will be open after power supply resume.

Main Menu INFORMATION

To open the main menu INFORMATION, press the right- or left-hand button once.
Return
Open
next
menu
To select the desired sub-menu use the up or down button.
Open the menu by pressing the right-hand button once.
To return to the main menu, press the left-hand button once.
OPERATION
Running mode: Water tank heating, Room heating, Room heating 1, Room heating 2, Auto ;
HEATCRVE
The setting of this submenu will affect the room temperature; CURVE is program that adjusts feed water
temperature according outdoor ambient temperature, factory setting is ambient temperature 0
temperature 40 , that is CURVE =40; the value of CURVE is adjustable from 22
the slope—two points decide one beeline, point one is (0,40), the other point could be (18,24), the point
(18,24) is not changing when changing the slope, because factory setting is that heat pump stops when
outdoor ambient temperature is 18 , so the feed water temperature should be 24 .
TEMPERATURE
Temperature items setting.

Control

General information

Sub

menus

OPER.WARMWATER
95
%
LANGUAGE
to 56 . How to change
20
HDO
CSP
as feed water