Relay: Converts 115 Volts to 24 Volts for thermostat, and sends signal to
combustion blower and gear motor to start or stop.
Convection Blower: Located behind enclosure on the left of stove. Blows heated
air into the room. It is energized by the fan and limit control.
Convection Blower Rheostat: To adjust fan speed and sound of convection
blower.
Fan & Limit Control: Serves dual purpose. 1. As a high limit, will shut off the
stoker unit to prevent overheating. If internal stove temperature reaches 200
degrees, control will shut off stoker unit, until temperature drops, which will then
allow stoker unit to be reactivated. 2. As a convection blower control, it starts the
convection blower when internal stove temperature reaches center pointer setting.
The convection blower will run as long as stove remains hot. When stove begins
to cool down to low setting on control, the convection blower will shut off.
Normal settings for control are: High limit (pointer on right) 200 degrees. Center
pointer (fan on) 160 degrees. Left pointer (fan off) 130 degrees. White button in
control must be pulled out for normal automatic operation. If continuous operation
of convection fan is desired, push white button in.
Zero Clearance Stove

CONTROLS AND THEIR FUNCTIONS

Thermostat: Top pointer is desired room
temperature. Bottom pointer is
thermometer. When room temperature drops
below setting, combustion blower and gear
motor will start. When room temperature
rises, combustion blower and gear motor
will stop.