Keystone Stoker Zero Clearance Installation Instructions Manual page 15

Zero clearance stove

Advertisement

Zero Clearance Stove
RELAY-receives signal from 24V thermostat to turn on or turn off gear motor.
CONVECTION BLOWER-when running, it will take cool air from room, and
force it through heated air chamber inside stove, and return heated air into room.
Blower can only be activated by Fan Limit Switch.
HOW TO REMOVE OR REPLACE GEAR MOTOR
TO REMOVE GEAR MOTOR: FIRST...Pull power cord pug from 115V outlet.
Remove 10-24 machine screw and then remove protective cage. Disconnect both
blue wire nuts marked. Remove both 10-24 machine screws from mounting
bracket Slide gear motor out of its track toward you, pusher bar will also come out
with gear motor. While pusher bar is out of its chute, clean chute area and remove
any obstructions. Check nylon screws on pusher bar (2 on each side) for wear or
breakage. (Replace if necessary) Slide pusher bar in and out of chute (should
move freely) check for sideward movement.
Adjust nylon screws on right side to allow only a slight sideward movement.
TO REPLACE GEAR MOTOR: -remove (4) 10-32 machine screws that hold
gear motor onto mounting bracket. Before removing gear motor from bracket,
look at position of gear motor; install new motor in exact same position before
reinstalling screws. Then reverse procedures and reinstall.
When replacing gear motor with a new one, both gear motor wires are black; either
wire may go to black or white wire from power supply.