Appendix 3: Resistance Table Of Outdoor Discharge Temperature Sensor(50K - Electrolux EXH09HL1W Service Manual

Inverter split system air conditioner
Hide thumbs Also See for EXH09HL1W:
Table of Contents

Advertisement

Resistance
Temp(℃)
-29
-28
-27
-26
-25
-24
-23
-22
-21
-20
-19
-18
-17
-16
-15
-14
-13
-12
-11
-10
-9
-8
-7
-6
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
8
9
210-10 ADL
Appendix 3: Resistance Table of Outdoor Discharge Temperature Sensor(50K)
Temp
Resistance
(kΩ)
(℃)
853.5
10
799.8
11
750
12
703.8
13
660.8
14
620.8
15
580.6
16
548.9
17
516.6
18
486.5
19
458.3
20
432
21
407.4
22
384.5
23
362.9
24
342.8
25
323.9
26
306.2
27
289.6
28
274
29
259.3
30
245.6
31
232.6
32
220.5
33
209
34
198.3
35
199.1
36
178.5
37
169.5
38
161
39
153
40
145.4
41
138.3
42
131.5
43
125.1
44
119.1
45
113.4
46
108
47
102.8
48
Temp
(kΩ)
(℃)
98
49
93.42
50
89.07
51
84.95
52
81.05
53
77.35
54
73.83
55
70.5
56
67.34
57
64.33
58
61.48
59
58.77
60
56.19
61
53.74
62
51.41
63
49.19
64
47.08
65
45.07
66
43.16
67
41.34
68
39.61
69
37.96
70
36.38
71
34.88
72
33.45
73
32.09
74
30.79
75
29.54
76
28.36
77
27.23
78
26.15
79
25.11
80
24.13
81
23.19
82
22.29
83
21.43
84
20.6
85
19.81
86
19.06
87
54/62
Resistance
Temp
(kΩ)
(℃)
18.34
88
17.65
89
16.99
90
16.36
91
15.75
92
15.17
93
14.62
94
14.09
95
13.58
96
13.09
97
12.62
98
12.17
99
11.74
100
11.32
101
10.93
102
10.54
103
10.18
104
9.827
105
9.489
106
9.165
107
8.854
108
8.555
109
8.268
110
7.991
111
7.726
112
7.47
113
7.224
114
6.998
115
6.761
116
6.542
117
6.331
118
6.129
119
5.933
120
5.746
121
5.565
122
5.39
123
5.222
124
5.06
125
4.904
126
599 75 60-77
Resistance(kΩ)
4.754
4.609
4.469
4.334
4.204
4.079
3.958
3.841
3.728
3.619
3.514
3.413
3.315
3.22
3.129
3.04
2.955
2.872
2.792
2.715
2.64
2.568
2.498
2.431
2.365
2.302
2.241
2.182
2.124
2.069
2.015
1.963
1.912
1.863
1.816
1.77
1.725
1.682
1.64

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Exh12hl1w

Table of Contents