Piping Length, Elevation, Flare Work & Torque Settings
Model
EXH09HL1W
EXH12HL1W
Flaring work.
Firmly hold copper pipe in a
die in the dimension shown in The table below
.
OUTER
DIAMETER(mm)
Max.
6,00
9,52
12,70
16
Connection Adjustment
1.
Align the pipes to be connected.
2.
Screw the flare nut with your
fingers,and the tighten it with
a spanner and torque wrench,
as shown in the following figure.
210-10 ADL
Piping
GAS
3/8
9.52mm
3/8
9.52mm
A(mm)
Min.
1,3
0,7
1,6
1,0
1,8
1,0
2,4
2,2
OUTER
DIAMETER(mm)
6,00
9,52
12,70
16
Standard
Length
LIQUID
(m)
1/4
5
6.00mm
1/4
5
6.00 mm
Caution:Excessive twisting may
break the nut,depending on the
installation conditions.
TIGHTENING
TORQUE(N/cm)
1570(160 kgf/cm)
2940(300 kgf/cm)
4900(500 kgf/cm)
6000(611 kgf/cm)
16/62
Max
Max
Elevation
Length
(m)
(m)
10
20
10
20
ADITINAL TIGHTENING
TORQUE(N/cm)
1960(200 kgf/cm)
3430(350 kgf/cm)
5390(550 kgf/cm)
6500(663 kgf/cm)
Additional
Refrigerant
(g/m)
20
20
599 75 60-77