Technical Data - Webasto Air Top 2000 D Service And Repair Manual

Table of Contents

Advertisement

Air Top 2000
4.

Technical Data

As long as no threshold values are given, the following
technical data are understood to include tolerances of
±10% usual for heaters at an ambient temperature of
+20 °C and at nominal voltage and conditions.
Air Heater
Mark of conformity
Heater type
Heat flow
Type of fuel
Fuel consumption
Nominal voltage
Operation voltage
Rated power consumption
Permitted ambient temp.:
- operation
Heater:
- storage
Dosing pump:
- operation
- storage
- operation
Control element:
- storage
Permitted combustion air
intake temperature
Setting range for
indoor temperature
Volume flow of heating air
against 0.5 bar
CO
in exhaust
2
(perm. functional range)
Dimensions air heater
Weight, heater
Operation
Control range
Control range
0.1 .. 0.2 kg/h (0.16..0.27 l/h)
Control range
Control range
Max.
Max.
Electrical Components:
Control unit, combustion air fan, dosing pump, timer*,
glow plug and control element are for 12 or 24 Volts
operation.
The components temperature limiter and flame detector
are independent of voltage.
*not for TRS
AT 2000 B
~ S 277
Air heater with
evaporator burner
1.1 – 2.0 kW
Fuel
12 Volt
10 ... 15 Volt
9 ...22 W
-40 ° ... +40 °C
-40 ° ... +85 °C
-40 ° ... +20 °C
-40 ° ... +85 °C
-40 ° ... +75 °C
-40 ° ... +85 °C
-40 ... +20 °C
+10 ... +45 °C
70 m
9.5 ... 10.5
Length 322 ± 2 mm
Width
Height 122 ± 1 mm
2.6 kg
4
Technical Data
AT 2000 D
~ S 270
0.9 – 2.0 kW
Diesel/Fuel oil (EL)
0.1 .. 0.21 kg/h (0.12 .. 0.24 l/h)
12 Volt
10 ... 15 Volt
20 ... 30 Volt
/h
3
9.5 ... 12.0
130 ± 1 mm
24 Volt
401