Air Top 2000
4.
Technical Data
As long as no threshold values are given, the following
technical data are understood to include tolerances of
±10% usual for heaters at an ambient temperature of
+20 °C and at nominal voltage and conditions.
Air Heater
Mark of conformity
Heater type
Heat flow
Type of fuel
Fuel consumption
Nominal voltage
Operation voltage
Rated power consumption
Permitted ambient temp.:
- operation
Heater:
- storage
Dosing pump:
- operation
- storage
- operation
Control element:
- storage
Permitted combustion air
intake temperature
Setting range for
indoor temperature
Volume flow of heating air
against 0.5 bar
CO
in exhaust
2
(perm. functional range)
Dimensions air heater
Weight, heater
Operation
Control range
Control range
0.1 .. 0.2 kg/h (0.16..0.27 l/h)
Control range
Control range
Max.
Max.
Electrical Components:
Control unit, combustion air fan, dosing pump, timer*,
glow plug and control element are for 12 or 24 Volts
operation.
The components temperature limiter and flame detector
are independent of voltage.
*not for TRS
AT 2000 B
~ S 277
Air heater with
evaporator burner
1.1 – 2.0 kW
Fuel
12 Volt
10 ... 15 Volt
9 ...22 W
-40 ° ... +40 °C
-40 ° ... +85 °C
-40 ° ... +20 °C
-40 ° ... +85 °C
-40 ° ... +75 °C
-40 ° ... +85 °C
-40 ... +20 °C
+10 ... +45 °C
70 m
9.5 ... 10.5
Length 322 ± 2 mm
Width
Height 122 ± 1 mm
2.6 kg
4
Technical Data
AT 2000 D
~ S 270
0.9 – 2.0 kW
Diesel/Fuel oil (EL)
0.1 .. 0.21 kg/h (0.12 .. 0.24 l/h)
12 Volt
10 ... 15 Volt
20 ... 30 Volt
/h
3
9.5 ... 12.0
130 ± 1 mm
24 Volt
401