Electrolux Affinity Service And Diagnostics page 62

Hide thumbs Also See for Affinity:
Table of Contents

Advertisement

Test (6)
Test (7)
Test (8)
Tests
1.
Is the door closing?
2.
Locate plug J-2 on the main board.
Measure voltage from J2-1 to ground.
1.
Remove the door lock assembly and
measure the resistance of the wax
motor.
1.
Disconnect the plug from the drive
motor and measure the resistance
between pins 4 and 5 on the motor.
Yes. Go to step (2).
If 0 volts is measured. Check the door strike.
If the door strike checks good, replace the
door switch assembly.
If 230 volts are measured, replace the main
control board.
If the wax motor is shorted or open, replace
the door lock assembly.
If the wax motor measures 800 to 1500
ohms, replace the main control board.
If the measurement is between 105 and 130
ohms, replace the motor control board.
If the measurement is outside of the range
of 105 -130 ohms, replace the motor.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents