Electrolux Affinity Service And Diagnostics page 64

Hide thumbs Also See for Affinity:
Table of Contents

Advertisement

Test 10
Tests
1.
Remove the belt from the motor and
spin the motor pulley. Does the motor
spin freely?
2.
Spin the tub pulley. Does the tub spin
freely?
3.
Disconnect the plug from the drive
motor and measure the resistance
between pins 4 and 5 on the motor.
4.
Disconnect the motor plug. Measure
resistance of motor windings by
measuring from pin 1 to pin 2, pin 1 to
pin 3, and pin 2 to pin 3. All readings
should measure between 4 to 6 ohms.
No. Replace the motor.
Yes. Go to step (3).
No. No. Check the tub bearings. If tub
bearings check good, check unit for
obstruction between tub and spin basket.
Yes. Go to step (3).
Measurement should be between 105 and
130 ohms. If meter reads outside of those
limits, replace the motor.
If the reading is between 105 and 130 ohms,
go to step (4).
If the readings are correct, replace the
motor control board.
If the readings are incorrect, replace the
motor.