Test (3)
Test (4)
Test (5)
Tests
1.
Check the drain hose for restrictions.
2.
Start the washer and check for 230
VAC at the drain pump.
1.
Inspect the wiring between the
pressure sensor and the main control
board.
1.
Is the water level above 120mm?
2.
Does water enter the washer
continuously?
3.
Remove power from the washer. Does
the water stop coming in?
4.
Check the pressure switch hose.
Restriction. Correct problem.
No restriction. Go to step (2).
Zero volts. Check wiring.
Wiring checks good. Replace main control
board.
230 volts is verified at the pump. Check for
blockage in pump. If there is no blockage,
replace the pump.
Defective wiring. Correct wiring.
Good wiring. Replace the pressure sensor. If
this does not correct the problem, replace
the main control board.
Yes. Go to step (2).
No. Go to step (4).
Yes. Go to step (3).
No. Replace the main control board.
Yes. Check valve wiring for shorts. If wiring
checks good, replace main control board.
No. Replace water valve assembly.
Is there a restriction of air leak? If not,
replace pressure switch.