Electrical Operation; Switching Off - Truma BOA Operating Instructions Manual

Gas and electric storage water heater
Hide thumbs Also See for BOA:
Table of Contents

Advertisement

Truma-Boiler
liquid gas storage
water heater with
additional electric
heating 230 - 240 V
Operating instructions
Always observe the oper-
ating instructions prior to
starting! The vehicle owner is
responsible for the correct
operation of the appliance.
The installer or vehicle owner
must apply the yellow sticker
with the warning information,
which is enclosed with the
appliance, to a place in the
vehicle where it is clearly
visible to all users (e.g. on the
wardrobe door)! Ask Truma to
send you stickers, if neces-
sary.
Attention: Before using the
first time, it is essential to
flush the entire water supply
through with clean warm
water. Always mount the
cowl cap when the water
heater is not being operated!
Drain the water heater if
there is a risk of frost! There
shall be no claims under
guarantee for damage cau-
sed by frost!
If connecting to a central
water supply (rural or city
connection) or when using
more powerful pumps, a
pressure reducer must be
used which prevents pres-
sures of greater than 280 kPa
occurring in the Boiler.
Safety/drain valve
e = Lever position
"Closed"
f = Lever position
"Drain"
Filling the Truma-
Boiler with water
1. Check that the safety/ drain
valve in the cold water intake
is closed: Lever should be in
horizontal position, position
(e).
2. Open hot tap in bathroom
or kitchen, with pre-selecting
mixing taps or single-lever fit-
tings set to "hot".
3. Switch on power for water
pump (main switch or pump
switch).
Leave the tap open to let air
escape while the water hea-
ter is filling. The heater is fil-
led when water flows out of
the tap.
Residues of frozen water can
prevent filling if there is a
frost. The water heater can be
defrosted by switching on the
heater for a short period
(max. 2 minutes). Frozen
pipes can be defrosted by
heating the room.
Note: If just the cold water
system is being used, with-
out water heater, the heater
tank is also filled up with
water. In order to avoid
damage through frost, the
water contents must be drai-
ned by actuating the safety/
drain valve, also when the
heater has not been used. As
an alternative, a shut-off valve
can be installed upstream of
the cold and hot water
connection.
Draining the water
heater
1. Disconnect power for
water pump (main switch or
pump switch).
2. Open hot water taps in
bathroom and kitchen.
3. Open safety/drain valve:
Lever in vertical position, po-
sition (f).
4. The water heater is now
drained directly to the outside
via the safety/drain valve.
Check that the water con-
tents have been completely
drained (10 or 14 litres).
Gas operation
a = Rotary control knob
On/Off and temperature
control
b = Green indicator lamp
"Operation"
c = Red indicator lamp
"Failure"
Gas operating
instructions
Attention: Never operate
the water heater without
water in it!
If the wall cowl is positioned
close to an opening window
(or hatch) - in particular direct-
ly under it - it must remain
closed when the water heater
is in use (see warning plate).
1. Remove cowl cover.
2. Open gas cylinder and
open quick-acting valve in the
gas supply line.
3. Select required water tem-
perature at rotary knob (b) in-
finitely variable from approx.
30° to 70°C.
4. Switch on water heater at
the slide switch (a) on the
control panel, green indicator
lamp "Operation" lights up.
5. If there is air in the gas
supply line, it may take up to
a minute before the gas is
available for combustion. If
the appliance switches to
"Failure" during this period,
switch off the appliance - wait
5 minutes - and switch on
again!

Switching off

(gas operation)
Switch off the water heater at
the slide switch (a).
Drain the water heater if
there is a risk of frost!
If the water heater is not to
be used for a longer period,
mount cowl cover (non-obser-
vance of this point can lead to
the function of the appliance
being impaired through water,
dirt or insects), close quick-ac-
ting valve in the gas supply
line and close the gas cylin-
der.
There shall be no claim
under guarantee if this
point is not observed.
Always remove the cowl
cover prior to operating the
water heater!
Red indicator lamp
"Failure"
The red indictor lamp (c)
lights up if there is a failure.
The reason for such an indi-
cation is, for example, no gas
available or air in the gas sup-
ply system, triggering of the
excess temperature monitor
etc. To unlock, switch off the
appliance, wait 5 minutes,
and switch on again.
In event of faults, always
contact the Truma Service
(please refer to page 9)

Electrical operation

230 - 240 V, 450 W
(Option)
d = Switch On/Off
When using the
vehicle switches
Refer to operating instruc-
tions of the vehicle manufac-
turer or see switch labels.
Electrical operating
instructions
Attention: Never operate
the water heater without
water in it!
Switch the switch (d) on the
control panel to „On" . The in-
dicator lamp indicates that
the electrical water heating is
switched on.
Note: The water temperature
cannot be selected, automatic
temperature limitation at
approx. 70°C! For a faster
heating up period the applian-
ce can be simultaneously
operated with gas and electri-
cal power.
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents