2.4
Mounting the Seismic Brackets (Continued)
5
Mark the position on the floor where the unit will be secured by using the bracket as a
tem plate. Drill holes and secure using the appropriate anchor bolts.
The drawing below looks down unto the bracket and the floor:
0.562 inch diameter for mounting 0.5 inch (13 mm) anchor bolts.
0.781 inch diameter for mounting 0.75 inch (19 mm) anchor bolts
Bracket Removal/Mounting Finished

2.5 Locking the Wheels

If the seismic mounts are not used (Section 2.4), the unit should be secured by locking the
wheels.
Tools and Materials Required:
• Phillips screwdriver.
Procedure:
Remove the lower front panel. The screws are in front of
1
the wheels.
2
Tighten the Phillips screw to stop the wheel from moving.
2
3
Repeat
for the other wheel.
4
Reinstall the lower front panel.
Wheels Locked
19
(such as Hilti #665927 (HSL M12/25)).