Connector Specifications; Digital Control Connector - Teac LX-100 Series Instruction Manual

Recording unit lx-100 series
Table of Contents

Advertisement

Connector Specifications

DIGITAL CONTROL connector

<Functions>
Contact input:
Status output:
<Input/Output Circuit>
Input Format
Output Format
<Connector>
Angled half pitch 36-pin
Pin Assignment
Pin No.
1
GND
2
RESERVED
3
RESERVED
4
GND
5
RESERVED
6
RESERVED
7
GND
8
RESERVED
9
RESERVED
10
RTCADJIN
11
RECFWDIN
12
RECIN
13
FWDIN
14
STOPIN
15
PAUSEIN
16
EVENTIN
17
PLOCKIN
18
GND
For PANEL LOCK input, the control buttons on the front panel of the LX cannot be used to perform operations.
The first signal locks the control buttons; the second signal releases the lock.
REC FWD, REC, FWD, STOP, PAUSE, event, panel lock, and internal clock
adjustment
REC, FWD, STOP, PAUSE, event, and panel lock
L level: 0.4 V or less
H level: Open or 2 V or more
Pulse width: 100 ms or more
Open drain, maximum sync current: 8 mA
DHA-RC36-R1xxx series
Signal
Function
Ground
Reserved
Reserved
Ground
Reserved
Reserved
Ground
Reserved
Reserved
Internal clock
ADjustment input
REC FWD input
REC input
FWD input
STOP input
PAUSE input
EVENT input
Panel Lock input
Ground
100 msec
or more
Lock
6-25
Connector Specifications
Pin No.
Signal
19
GND
20
RESERVED
21
RESERVED
22
AGND
23
AGND
24
AGND
25
AGND
26
RESERVED
27
RESERVED
28
NC
29
NC
30
RECSTS
31
FWDSTS
32
STOPSTS
33
PAUSESTS
34
EVENTSTS
35
PLOCKSTS
36
GND
1 sec or more
Release
Function
Ground
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
REC output
FWD output
STOP output
PAUSE output
Event output
Panel Lock output
Ground

Hide quick links: