CHARGING PROGRAMS AND OPTIONS COMBINATIONS
DESULPHATION
15.8V
15.8V
AGM
+
15.8V
RECOND
+
15.8V
AGM
RECOND
+
+
15.8V
15.8V
+
AGM
15.8V
+
RECOND
15.8V
+
+
AGM
RECOND
Time limit:
SOFT START
BULK
0.8A until 12.6V
Increasing voltage to
14.4V. 0.8A
0.8A until 12.6V
Increasing voltage to
14.7V. 0.8A
0.8A until 12.6V
Increasing voltage to
14.4V. 0.8A
0.8A until 12.6V
Increasing voltage to
14.7V. 0.8A
5A until 12.6V
Increasing voltage to
14.4V. 5A
5A until 12.6V
Increasing voltage to
14.7V. 5A
5A until 12.6V
Increasing voltage to
14.4V. 5A
5A until 12.6V
Increasing voltage to
14.7V. 5A
Max 8h
Max 20h
ABSORPTION
ANALYSE
Declining current
Checks if voltage
14.4V
drops to 12V
Declining current
Checks if voltage
14.7V
drops to 12V
Declining current
Checks if voltage
14.4V
drops to 12V
Declining current
Checks if voltage
14.7V
drops to 12V
Declining current
Checks if voltage
14.4V
drops to 12V
Declining current
Checks if voltage
14.7V
drops to 12V
Declining current
Checks if voltage
14.4V
drops to 12V
Declining current
Checks if voltage
14.7V
drops to 12V
Max 8h
3 minutes
RECOND
FLOAT
13.6V
0.8A
13.6V
0.8A
Max 15.8V
13.6V
0.3A
0.8A
Max 15.8V
13.6V
0.3A
0.8A
13.6V
5A
13.6V
5A
Max 15.8V
13.6V
1.8A
5A
Max 15.8V
13.6V
1.8A
5A
10days
2h or 6h
Charge cycle restarts
if voltage drops
PULSE
12.7V–14.4V
0.8–0.3A
12.7V–14.7V
0.8–0.3A
12.7V–14.4V
0.8–0.3A
12.7V–14.7V
0.8–0.3A
12.7V–14.4V
5–2.5A
12.7V–14.7V
5–2.5A
12.7V–14.4V
5–2.5A
12.7V–14.7V
5–2.5A
Charge cycle restarts
if voltage drops