Using the flat screwdriver, release the tabs on the
Access Cover (20), and lift the Access Cover off the
elliptical. Then, remove the seven indicated M4 x
16mm Screws (106), and remove the Left Shield (19).
20
Next, rotate the Large Pulley (74) until a Pulley Magnet
(75) is aligned with the Reed Switch (69). Loosen, but
do not remove, the indicated M4 x 16mm Screw (106),
and slide the Reed Switch slightly toward or away from
the Pulley Magnet. Then, retighten the Screw.
69
74
Plug in the power cord and rotate the large pulley for
a moment. Repeat these actions until the console
displays correct feedback. When the reed switch is
correctly adjusted, reattach the left shield, the access
cover, the left disc, and the left pedal arm sleeve.
106
19
106
106
75
106
HOW TO ADJUST THE DRIVE BELT
If you can feel the pedals slip while you are pedaling,
even when the resistance is adjusted to the highest
level, the drive belt may need to be adjusted.
To adjust the drive belt, first unplug the power cord.
Next, see HOW TO ADJUST THE REED SWITCH
beginning on page 20 and remove the left pedal arm
sleeve, the left disc, the access cover, and the left
shield.
Next, loosen the Pivot Screw (97). Tighten the Belt
Adjustment Screw (85) until the Drive Belt (38) is tight.
When the Drive Belt is tight, tighten the Pivot Screw.
106
When you are finished, reattach the left shield, the
access cover, the left disc, and the left pedal arm
sleeve.
21
38
97
85

Advertisement