Fisher & Paykel PHASE 6 Series 11 Service Manual page 41

120v 60 hz electronic washing machine
Hide thumbs Also See for PHASE 6 Series 11:
Table of Contents

Advertisement

517766
235.
(11101011) Phase 6 - Lid Lock Short Circuit
Lid Lock fault, not activated when instructed to by the motor controller
Primary Fault:
Action:
ohms, if not within 5 ohms replace the Lid Lock.
236.
(11101100) Phase 6 - Incompatible EEPROM Version
Failure to start and fault immediately displayed
Primary Fault:
Action:
237.
(11101111) Phase 6 - Temperature Sensor Error
The electronics have picked up a continuity problem, same as fault code 10 or 41.
Primary Fault:
thermistor.
Action:
Secondary Source:
check connections.
Action: Replace motor controller if connections look fine and the fault still occurs.
238.
(11101110) Phase 6 - Lid Lock Fail In-Line Test (1)
Final on line tests, final check before going to the field.
239.
(11101111) Phase 6 - Lid Lock Fail In-Line Test (2)
Final on line tests, final check before going to the field
240.
(11110000) Phase 6 - Hall Out Of Order. RPS Fault
Same as previous Hall Error faults, just an extra fault code for phase 6, see code
130,131 for directions.
241.
(11110001) Phase 6 - Function Time Out
Display crashed
Primary Fault: Display has failed
Action: Replace Display Module
Secondary Fault: Motor controller has failed
Action: Replace Motor controller
242.
(11110010) Phase 6 - OOB Hit Greater than Max for 5 Sec
Out Of Balance warning to the user, additional fault code for Phase 6
Primary Fault: Machine has detected the Tub movement to be excessive or the
Micro switch is permanently on or harness to it is disconnected.
Action: See fault code 43 for details.
243.
(1110011) Phase 6 - Stepper Test Failure
Rotor Position Sensor Fault, the motor controller has attempted a motor step test
and found the motor has not stepped to the correct position.
Primary Fault: Wiring
Action: See Fault code 53 and 54.
Lid Lock mechanism has jammed or failed
Check resistance across the connections, should be around 73
Motor controller is the wrong one.
Replace motor controller.
The sensor has failed either in the harness or connection to the
Replace the Thermistor (temperature sensor)
Motor controller has failed to read the temperature,
- 41 -
March 2003

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gwl11 ecosmartIwl12Gwl03Gwl08Gwl10

Table of Contents