Fisher & Paykel PHASE 6 Series 11 Service Manual page 31

120v 60 hz electronic washing machine
Hide thumbs Also See for PHASE 6 Series 11:
Table of Contents

Advertisement

517766
3.
Replace the Motor Controller module.
42.
(00101010) Phase 1 – Rotor Fault
Primary Source:
feedback.
Action:
Restart.
43.
(00101011) Phase 1 to 6 - OOB Switch Fault
The Motor Controller module has found that the signal returning from the out of
balance switch indicates that the switch is permanently on or the harness to it is
disconnected.
Primary Source:
Action:
1)
Check that the out of balance switch is free to move.
2)
Check that no harnesses are blocking switch movement.
3)
Check that the switch operates correctly when activated. Replace the switch
if suspect.
4)
If the out of balance micro switch shows signs of corrosion, replace the
switch and switch harness, and fit a condensation kit to the console area if
not incorporated in the top deck.
5)
Check the level of the machine and also the bias spring.
Secondary Source:
Action:
Check the harness to the switch is connected correctly. The terminals should be
connected to the normally closed position. If the harness terminals show signs of
corrosion, then fit a new harness.
Tertiary Source:
Action:
Replace Motor Controller module.(Display Module Phase 1)
44.
(00101100) Phase 2 to 6 - Water in Tub during Spin
The Motor Controller has sensed a water level in the Tub during spin. This may be
caused by a slow pump out rate due to a partial blockage in the pump hose or
pump.
Primary Source:
Action:
1)
Check that the drain hose is not squashed or kinked.
2)
Check the length of the drain hose and try to reduce the length if excessively
long. A 39 inch (1 metre) extension hose of the same diameter fitted to the
existing drain hose is the maximum allowable length.
3)
If the Tub is empty of water, remove the pump from the pump housing and
check that it is not blocked. Also check that the drain hose is not blocked.
4)
If the Tub contains water, then service the pump from the top of the machine
by removing the top deck and basket. Bail out the water, remove the pump
cap and hood and clear the pump of any obstruction.
5) Check that water is not siphoning back into the machine when the pump turns off
when the spin speed reaches 700 rpm
Secondary Source:
Action:
Replace Motor Controller module.
The Motor Controller has had some confusing information
Turn off Smartdrive at the wall and back on again after 5 seconds.
Mechanical.
Wiring.
Motor Controller module.(Display Module Phase1 )
Pump System.
Motor Controller module.
- 31 -
March 2003

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gwl11 ecosmartIwl12Gwl03Gwl08Gwl10

Table of Contents