Special Application
Receptacle
Twelve-Pin
Receptacle
Specifications
(Model 2000)
\
,
Contacts
Function
Description
b 5 & b 6 Zero-Position
Switch
Gonnects to an internal single-pole single-throw
normally open switch. Contacts are closed when
the slide tray is at any position other than zero,
These leads connect only to the switch terminals.
Do not exceed a switching load of a A at 30 V ac.
a 6 & b 4 Shutter Switch
Connects to an internal single-pole single-throw
normally closed switch. Contacts are open when a
slide is in the projector gate and the shutter is
open. These leads connect only to the switch
terminals. Do not exceed a switching load of 1A at
30 V ac.
a 1 & b 4 Supply Voltage
for External
Units
Provision of max. 25.5 V/max. 0.5 A direct voltage
on the 12-pin socket is given as soon as the
projector is switched on.
b 3 & b 4 Forward Tray
Cycle
Connects to the forward tray-advance circuitry in
the projector. These contacts are connected
internally to the remote-oontrol socket and an
electrical connection made at either socket will
result in a forward cycle.
b 2 & b 4 Reverse Tray
Cycle
Connects to the reverse tray-advance circuitry in
the projector. These contacts are connected
internally to the remote-control socket and an
electrical connection made at either socket will
result in a reverse cycle.
a 3 & a 4 External Lamp
Control
"Dissolve"
Gonnects to al to turn lamp on; a4 is live only
when the EXT/INT lamp switch is in the EXT/
position.