Epson S1S65010 Technical Manual page 32

Network camera controller with jpeg encorder
Table of Contents

Advertisement

<LAN debugging>
Debugging of the reference code is also possible over a LAN cable connected to a PC. Note, however,
that a direct connection to a PC requires a cross cable.
The following is the procedure.
1. Connect the two boards (main and camera).
2. Connect the power supply to the power supply connector.
3. Turn on the green power supply LED on the board to light.
4. Connect the kit to the PC with an Ethernet cross cable or to a hub with a straight cable.
5. Change the PC's IP address to match the target.
This evaluation board set the default IP address 192.168.1.253, so make sure that there are no
duplications of IP addresses.
We recommend the following Japanese free software for changing the PC's IP address.
Win95 Series: KemaNet
Win2K Series: valhell IP config
6. Test the cable connection and IP address setting with the following console command.
If everything is functioning correctly, there should be a response similar to the following.
------------------------------------------------
Pinging 192.168.1.253 with 32 bytes of data:
Reply from 192.168.1.253: bytes=32 time<10ms TTL=128
Reply from 192.168.1.253: bytes=32 time<10ms TTL=128
Reply from 192.168.1.253: bytes=32 time<10ms TTL=128
Reply from 192.168.1.253: bytes=32 time<10ms TTL=128
Ping statistics for 192.168.1.253:
Approximate round trip times in milli-seconds:
------------------------------------------------
7. Boot the PC's Web browser (Internet Explorer, Netscape, etc.)
If the Java plug-in has not been installed, download it from the following URL.
http://java.sun.com/getjava/ja/install-windows.html
8. Access the following address with the Web browser.
http://192.168.1.253/
9. Click on "Continuous image" on the menu screen that appears.
10. Input the user name and password, then start capturing/monitoring. This board ships with only one
user and the following default password.
User name: root
password: administrator
S1S65010
Evaluation Board Technical Manual (Rev. 1.1e)
http://www.vector.co.jp/soft/win95/net/se060975.html
http://www.vector.co.jp/soft/winnt/net/se132582.html
ping 192.168.1.253
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
Minimum = 0ms, Maximum =
0ms, Average =
EPSON