Mitsubishi SCM40ZJ-S Service Manual page 128

Outdoor & indoor unit inverter multi-split system, residential air conditioners (split system, air to air heat pump type)
Hide thumbs Also See for SCM40ZJ-S:
Table of Contents

Advertisement

Error code
Remote controller:
E47
1. Applicable model
Model SCM40, 45, 50, 60, 71, 80
only
2. Error detection method
Error is displayed if the
converter voltage exceeds
DC340V (3 times within 20
minutes). Remote controller
may be set after 3 minutes
delay.
3. Condition of Error displayed
Same as above
4. Presumable cause
• Defective outdoor sub PCB
• Dust on outdoor sub PCB
• Anomalous power supply
Note:
LED
Green
Red
Indoor Keeps flashing Stays OFF
2 times flash
Outdoor
5. Troubleshooting
Diagnosis
Is the power supply normal?
YES
Is voltage
within the specified range?
YES
Check
soldered surfaces on the
outdoor sub PCB for foreign matter
like dust, fouling,
etc.
127
-
Content
Active filter voltage error
( Model SCM40, 45, 50, 60, 71, 80 )
NO
NO
NO
YES
-
'11 • SCM-SM-110
Countermeasure
Restore normal condition.
Restore normal condition.
Remove foreign matter like
dust, fouling, etc.
Defective outdoor sub PCB
➞ Replace.