10) Always do a final set up by checking the gas flow rate by clocking the meter.
Do a complete combustion check with proper test equipment to obtain the
best and safe CO² , O², and CO results. This test must be done by a quali-
fied technician. The maximum CO² level for Natural Gas is 10%.
The maximum CO² level for Propane Gas is 12%. The recommended flue gas
temperature is from 350 degrees Fahrenheit to 550 degrees Fahrenheit.
Fill out the installation data on the label described below and explain the
burner's essential functions (starting and stopping) to the owner.
Do not forget to give the dealer or service company's name and address.

INSTALLATION DATA

Note: This label is supplied in the package with the burner and should be
filled out and affixed to the appliance when the conversion burner is
installed.

SERIAL NUMBER IDENTIFICATION

Your Riello burner may have been manufactured in more than one location and therefore there are two possible serial
number identification.
The Riello 9 character serial number, example,
06 01 12345, is identified as follows:
06
= Last two digits of the year of manufacture;
01
= Week of manufacture;
12345
= Increment of 1 for each burner produced – specific
to product code – reset to zero each January 1
The Riello 15 character serial number, example,
06 A 8511111 00025, is identified as follows:
06
= Last two digits of the year of manu-
facture;
A
= BI-week of manufacture;
8511111 = Burner product code;
00025
= Increment of 1 for each burner pro-
duced – specific to product code –
reset to zero each January 1
BURNER COMPONENTS
IDENTIFICATION
1 Air damper
2 Servomotor
2 Motor
4 Air pressure switch
5 Wiring terminal block
6 Control box RMG 88.62
7 Reset button with lock-out lamp
3245
st
.
(06)
Year of
manufacture
st
.
7
6
5
(06)
(01)
Year of
BI-week of
manufacture
manufacture
(A)
(8511111)
BI-week of
BI-week of
manufacture
manufacture
4
3
GB
(12345)
Increment
(00025)
Increment
1
2
D7338
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Riello 40G900

Table of Contents