Technical Description Of The Burner; Technical Data; Electrical Data; Burner Models Designation - Riello RS 160/EV BLU Installation, Use And Maintenance Instructions

Forced draught gas burners
Table of Contents

Advertisement

3

Technical description of the burner

3.1

Technical data

Model
High
Output
(1)
Low
Fuel
- Max delivery
- Pressure at maximum delivery
Operation
Standard application
Ambient temperature
Combustion air temperature
Noise levels
(3)
Reference conditions: ambient temperature 68 °F (20 °C) - Barometric pressure 394" WC - Altitude 329 ft.
(1)
Pressure at test point 21)(Fig. 5), with zero pressure in the combustion chamber, with open gas ring 2)(Fig. 21) at maximum burner output
(2)
Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output.
(3)
*
Firing rate for C-UL Canadian Listing
3.2

Electrical data

Model
Control circuit power supply
Main power supply (+/-10%)
Fan motor (IE2/EPACT)
Ignition transformer
Electrical power consumption
Electrical control circuit cons.
Total electrical consumption
Electrical protection
3.3

Burner models designation

Model
RS 160/EV BLU
RS 160/EV BLU
20094580
Technical description of the burner
kW
MBtu/hr
kW
MBtu/hr
SCFH
natural gas
" WC
(2)
°F
°F max
dB(A)
V/Ph/Hz
V/Ph/Hz
rpm
HP
V
A
V1 - V2
I1 - I2
W
W max
W
Code
20076794
20101817
RS 160/EV BLU
1032 - 2065 (1847 *)
3521 - 7046 (6302 *)
Low - high or modulating
Boilers: water, steam, thermal oil
32 - 104 (0 - 40 °C)
RS 160/EV BLU
208-220/3/60
3500
7.5
208-230
18.6
120 V - 1 x 8 kV
1.6 A - 20 mA
6300
750
7050
RBNA code
Main Voltage
C9344710
C9344701
6
GB
333
1136
Natural gas
7046
7
140 (60 °C)
83.1
120/1/60
460/3/60
575/3/60
3500
7.5
460
9.3
6300
750
7050
NEMA 1
Flame safeguard
460/3/60
Burner mounted
575/3/60
Burner mounted
Tab. A
3500
7.5
575
7.4
6250
750
7000
Tab. B
Tab. C

Advertisement

Table of Contents
loading

This manual is also suitable for:

C9344710C9344701