Motorola RFS7000 Series Troubleshooting Manual page 37

Rf switch
Hide thumbs Also See for RFS7000 Series:
Table of Contents

Advertisement

3.3 KERN Messages (Continued)
Module
flowctl.c
flowctl.c
flowctl.c
flowctl.c
flowctl.c
flowctl.c
flowctl.c
flowctl.c
flowctl.c
flowctl.c
Message
PKT_WARN( ""fc:mu removed
before fc ack on prtl
""MACSTR,);
PKT_WARN( ""fc:dropped
assoc resp pkt to ""MACSTR,);
PKT_INFO( ""fc:dropped %d
consec pkts to ""MACSTR,);
PKT_INFO( ""fc:mu
[""MACSTR""] in psp, dropped
packet %d"",);
PKT_ERR( MACSTR"" prtl
window wrap curr=%u,
new=%u"",);
PKT_INFO( MACSTR"" fc
window wrap curr=%u,
new=%u"",);
PKT_ERR( MACSTR"" wisp
seq %u != fc seq=%u setting
to %u"",);
PKT_INFO( ""fc allocs:q full""
);
PKT_INFO( ""fc:allocs back
down to %u"", curr_fc_allocs
);
PKT_ERR( ""fc alloc:no
memory for fc allocs"" );
Network Events & Kern Messages
Description
An ACK for WISP packet has
arrived, but the corresponding
receiving station has been
deleted from system.
An association response or
reassociation response
packet has not transmitted
successfully.
More than 5 packets in a row
to the same station have
failed.
Received a transmit result for
a Mobile Unit in PSP mode.
Detected a wrap around in the
WISP flow control window.
Note: It is expected to see the
wrap around from 65535 to
zero. This is not an error
condition it is caused by a
programming error.
Detected a wrap around in the
WISP flow control window.
Note: It is expected to see the
wrap around from 65535 to
zero. This is not an error
condition it is caused by a
programming error.
WISP sequence with a radio
has become out of sync.
Resync to the new number.
Number of pending packets in
the switch has exceed the
limit. The limit is 10,000 for
RFS7000.
The number of pending
packets has fallen back below
the limit.
Request from the operating
system for a new packet has
failed.
3-15

Advertisement

Table of Contents
loading

Table of Contents