Ancillary Product Specifications
Model 267 Pressure Transducer
4.2 Model 267 Pressure Transducer
Performance Data
1
Accuracy
RSS (at constant temperature)
Non-linearity (BFSL)
Hysteresis
Non-repeatability
2
Thermal Effects
°
Compensated Range
F (
°
Zero/Span Shift % FS/
F (
Maximum Line Pressure
Overpressure
Warm-up Shift
Position Effect
Unit is factory calibrated at 0g effect in the
vertical position
Environmental Data
Temperature
3
Operating
°
F (
°
C)
°
°
Storage
F (
C)
Physical Description
Case
Dimensions
Electrical Connection
Electrical Termination
Pressure Fittings
Weight (approximate)
Pressure Media
Typically air or similar non-conducting gases
28
MKT-0262 MPC-1748 Rev 02/13
Table 2. Model 267 Pressure Transducer
Standard
± 1.0 % FS
± 0.98 % FS
0.10% FS
0.05% FS
°
C)
40 - 150 (5 - 65)
°
C)
± 0.033 (± 0.06)
10 psi
Up to 10 psi (range dependent)
± 0.1% FS Total
Range
To 0.5" WC
To 1.0" WC
0 - +150 (-18 - +65)
+65 - +180 (-54 - +82)
IP65/NEMA plastic-filled polycarbonate (UL94 V-0 Approved)
6.20" (158 mm) W x 2.68" (68 mm) H x 3.65" (93 mm) D
Screw type terminal strip
PG-9/PG13.5 Strain relief, 1/2" conduit opening, or 9-pin D-sub connector
NOTE: 9-pin D-sub connector is not suitable for NEMA4/IP-65 environments
3/16" O.D. barbed brass for 1/4" push-on tubing (Standard)
Static Pressure Probe (Optional)
1/4" NPTF brass (Optional)
9 ounces (255 g)
Optional
± 0.4 % FS ± 0.25 % FS
± 0.38 % FS ± 0.22 % FS
0.10% FS 0.10% FS
0.05% FS 0.05% FS
Zero Offset (% FS/G)
0.60
0.50