Installing The Air Conditioner - Dometic 620526.336 Installation Instructions Manual

Roof-top air conditioner
Hide thumbs Also See for 620526.336:
Table of Contents

Advertisement

G. Installing The Air Conditioner
Installing Unit with 3105007 or 3105935 Return Air
Kit. For unit with Genesis Air Filtration System, see
page 11.
FIG. 12
Ceiling Template
Return Air
Grill
1. Installation Of Ceiling Template
a. Check gasket alignment of the air conditioner
over the roof opening and adjust if necessary.
Unit may be moved from below by slightly lift-
ing and moving. See FIG. 13.
Center Unit From Below
FIG. 13
Roof
Gasket
b. Remove return air cover and ceiling template
from the 3105007 or 3105935 carton.
c. Locate the four (8" x 1/4- 20) unit mounting bolts,
junction box cover and Romex connector in the
3107180 bolt kit.
d. Pull down the unit's electrical cord and fasten
the junction box with screws to the framing in
the front of the 14-1/4" x 14-1/4" (±1/8") open-
ing. See FIG. 14.
FIG. 14
DC Power
Furnace
Unit CCC
Connectors
Pull Electrical
Cord Down
Fasten Jct. Box To
Front Of Opening
Divider Plate
Return Air
Cover
Gasket
AC Power
Supply
620515, 620525, 620526, 630515 & 630516 Installation Instructions
e. Install the Romex connector in the junction box.
f.
Hold the ceiling template up to the 14-1/4" x
14-1/4" (±1/8") opening. Be sure the large plate
faces the rear of the RV.
g. Start each mounting bolt through the ceiling tem-
plate and up into the unit base pan by hand.
Install wood screw in each end of the ceiling
template. This insures a tight fit of the return air
cover to ceiling. See FIG. 14. Evenly tighten
mounting bolts to compress gasket to 1/2"
this will be a torque of 40 - 50 inch pounds.
The bolts are self locking so over tighten-
ing is not necessary. See FIG. 15.
FIG. 15
Screws
Finger
Tight
If bolts are left loose there may not be ad-
equate roof seal or if over tightened, damage
may occur to the air conditioner base or ceil-
ing template. Tighten to specifications listed
in this manual.
2. Installation of Divider Plate
a. Measure the ceiling to roof thickness:
If distance is 2.0" - 3-3/4", remove perfo-
rated tab from divider plate.
If distance is 3-3/4" - 5-1/2", remove no tabs.
b. Remove the backing paper from double sided
tape located on ceiling template. See FIG. 16.
FIG. 16
10
Front of Vehicle
Tighten to
compress gasket
to 1/2"
CAUTION
Roof
Gasket

Advertisement

Table of Contents
loading