Dometic 620526.336 Installation Instructions Manual

Dometic 620526.336 Installation Instructions Manual

Roof-top air conditioner
Hide thumbs Also See for 620526.336:

Advertisement

USA
SERVICE OFFICE
Dometic Corporation
2320 Industrial Parkway
Elkhart, IN 46515
574-294-2511
CANADA
Dometic Distribution
866 Langs Drive
Cambridge, Ontario
CANADA N3H 2N7
519-653-4390
For Service Center
Assistance Call:
800-544-4881
C
US
INSTALLATION
INSTRUCTIONS
REVISION:
Form No. 3309083.016 2/05
(Replaces 3309083.008)
(French 3309084.014)
©2005 Dometic Corporation
LaGrange, IN 46761
620515, 620525, 620526
Roof-Top Air Conditioner
Roof Top Heat Pump
used with one of following:
3105007 Return Air Cover
3105935 Quick Cool Return Air Cover
3308120 Genesis Air Filtration System
3109228.001 Comfort Control Center
THIS UNIT IS DESIGNED FOR OEM INSTALLATION
ALL INITIAL INSTALLATIONS MUST BE APPROVED BY THE SALES DEPT.
This manual must be read and un-
derstood before installation, ad-
justment, service, or maintenance
is performed. This unit must be in-
stalled by a qualified service tech-
nician. Modification of this product
can be extremely hazardous and
could result in personal injury or
property damage.
Important:
These Instructions
must stay with unit.
Owner read carefully.
620515, 620525, 620526, 630515 & 630516 Installation Instructions
MODEL
630515, 630516
and
Lire et comprendre ce manuel avant de
procéder à l'installation, à des réglages,
de l'entretien ou des réparations.
L'installation de cet appareil doit être
effectuée par un réparateur qualifié.
Toute modification de cet appareil peut
être extrêmement dangereuse et
entraîner des blessures ou dommages
matériels.
1
RECORD THIS UNIT INFORMATION FOR
FUTURE REFERENCE:
Model Number
Serial Number
Date Purchased
TM
Models
620515.331
620526.336
620515.336
630515.331
620525.331
630515.336
620525.336
630516.331
620526.331
630516.336

Advertisement

Table of Contents
loading

Summary of Contents for Dometic 620526.336

  • Page 1 Models INSTALLATION 620515.331 620526.336 620515.336 630515.331 INSTRUCTIONS 620525.331 630515.336 620525.336 630516.331 620526.331 630516.336 REVISION: Form No. 3309083.016 2/05 Important: These Instructions (Replaces 3309083.008) must stay with unit. (French 3309084.014) Owner read carefully. ©2005 Dometic Corporation LaGrange, IN 46761...
  • Page 2: Features

    620515, 620525, 620526, 630515 & 630516 Installation Instructions SAFETY INSTRUCTIONS GENERAL INFORMATION Product features or specifications as described or illus- This manual has safety information and instruc- trated are subject to change without notice. tions to help users eliminate or reduce the risk of B.
  • Page 3 620515, 620525, 620526, 630515 & 630516 Installation Instructions...
  • Page 4: Installation Instructions

    1. Read Installation and Operating Instructions care- fully before attempting to start your air conditioner installation. 2. Dometic Corporation will not be liable for any dam- It is preferred that the air conditioner be installed on ages or injury incurred due to failure in following a relatively flat and level roof section measured these instructions.
  • Page 5: Roof Preparation

    620515, 620525, 620526, 630515 & 630516 Installation Instructions FIG. 4 4" FIG. 5 4" 7-1/8” REAR 4-1/8” 21-3/8” UNIT Center Line 14-1/4" x 14-1/4” (±1/8”) OPENING of Unit 7-1/8” KEEP THESE AREAS d. If the opening exceeds 14-3/8" x 14-3/8", it will 12"...
  • Page 6 Return air to the air conditioner must be filtered the ductwork will not collapse or bend during to prevent dirt accumulation on air conditioner and after the installation. Dometic Corporation cooling surface. will not be liable for roof structural or ceiling 5.
  • Page 7 Corporation in writing. The following instructions are LOW VOLTAGE WIRES: CCC, CONTROL CABLE(S) or 7-Wire Analog Cable 12VDC based upon the use of 3105007 Dometic Return Air Kit, Furnace Load Shed 3105935 Dometic Return Air Kit or 3308120 Genesis Air Sensors SIDE VIEW Filtration System and a 3109228.001 Comfort Control...
  • Page 8: Dometic Comfort Control Center & Cable

    This supply line must be located in the front E. Dometic Comfort Control Center™ & Cable portion of the 14-1/4" x 14-1/4" (±1/8") opening. Installation The power MUST be on a separate 20 Amp time 1.
  • Page 9: Placing Air Conditioner On The Roof

    620515, 620525, 620526, 630515 & 630516 Installation Instructions FIG. 8A F. Placing Air Conditioner On The Roof FIG. 10 FIG. 8B FIG. 8C Pin 1 RJ-11-6C4P Connector This unit weighs approximately 100 pounds. To prevent back injury, use a mechanical hoist Flat Four Conductor Cable to place Air Conditioner on roof.
  • Page 10: Installing The Air Conditioner

    620515, 620525, 620526, 630515 & 630516 Installation Instructions G. Installing The Air Conditioner e. Install the Romex connector in the junction box. Hold the ceiling template up to the 14-1/4" x Installing Unit with 3105007 or 3105935 Return Air 14-1/4" (±1/8") opening. Be sure the large plate Kit.
  • Page 11 620515, 620525, 620526, 630515 & 630516 Installation Instructions c. Place divider plate up to bottom of air condi- Installing unit with 3308120 Genesis Air Filtration tioner base pan firmly. The foam tape on the System Return Air Kit. For unit with 3105007 or divider plate must seal to bottom of base pan.
  • Page 12 Rear Flange On Ceiling Template ter duct. This duct adapter must be approved by Dometic. d. Start each mounting bolt through the ceiling tem- a. Check gasket alignment of the air conditioner plate and up into the unit base pan by hand.
  • Page 13: Wiring The System

    620515, 620525, 620526, 630515 & 630516 Installation Instructions H. Wiring The System • Place the foam divider in the return air open- ing above the center duct before installing Reach up into the return air opening and pull the re- ceiling template.
  • Page 14 620515, 620525, 620526, 630515 & 630516 Installation Instructions a. Route power supply line through Romex con- Installing unit with 3308120 Genesis Air Filtra- nector into junction box on side away from the tion System Return Air Kit. For 3105007 or ceiling template.
  • Page 15: System Configuration/Reset/Check Out

    620515, 620525, 620526, 630515 & 630516 Installation Instructions J. System Configuration, Reset & Check Out FIG. 26C Now that the system is installed, it is necessary to check all Use Flat Blade Screw- operations and then configure the electronics. Refer to the DO NOT USE driver Wider Than Dip Operating manual for a description of the air conditioner...
  • Page 16: Wiring Diagram

    BREAKER BOX BREAKER BOX 2 WIRES 2 WIRES 4-CONDUCTOR 4-CONDUCTOR CONTROL CABLE CONTROL CABLE OPTIONAL OPTIONAL FURNACE FURNACE DOMETIC COMFORT DOMETIC COMFORT CONTROL CENTER CONTROL CENTER FURNACE FURNACE FURNACE 2 WIRES 2 WIRES 14-1/4" x 14-1/4" 14-1/4" x 14-1/4" (±1/8”) OPENING (±1/8”) OPENING...

Table of Contents