Dometic 641415.30 series Installation Instructions Manual

Dometic 641415.30 series Installation Instructions Manual

Air conditioner, air conditioner w/electric heat, heat pump

Advertisement

USA
SERVICE OFFICE
Dometic Corporation
1120 North Main Street
Elkhart, IN 46514
CANADA
Dometic Corporation
46 Zatonski, Unit 3
Brantford, Ontario
CANADA N3T 5L8
SERVICE CENTER &
DEALER LOCATIONS
Please Visit:
www.eDometic.com

INSTALLATION INSTRUCTIONS

REVISION A
Form No. 3312500.030 09/16
(French 3312709.037_A)
©2016 Dometic Corporation
LaGrange, IN 46761
Description
Model
641415
641416
641515
641516
641715
Air Conditioner
641716
641815
641816
641915
641916
641432
641435
641535
641732
Air Conditioner
W/Electric Heat
641735
641835
641932
641935
651515
651516
651815
Heat Pump
651816
651915
651916
Note: Installation requires a #2 phillips screwdriver with 9/32" maximum diameter x 1-1/4" minimum length.
This manual must be read and
understood before installation,
adjustment, service, or mainte-
nance is performed. This unit must
be installed by a qualified service
technician. Modification of this
product can be extremely hazard-
ous and could result in personal
injury or property damage.
Read these instructions carefully. These
instructions MUST stay with this product.
Roof Top Unit
Use With Air Distribution Box
3310742.XXX
Control
Analog Board Built In
Analog Board Built In
CCC Board Built In
CCC Board Built In
Digital Board Built In
Digital Board Built In
CCC 2 Board Built In
CCC 2 Board Built In
LCD Board Built In
LCD Board Built In
Analog Board Built In
Analog Board Built In
CCC Board Built In
Digital Board Built In
Digital Board Built In
CCC 2 Board Built In
LCD Board Built In
LCD Board Built In
CCC Board Built In
CCC Board Built In
CCC 2 Board Built In
CCC 2 Board Built In
LCD Board Built In
LCD Board Built In
Lire et comprendre ce manuel avant de
procéder à l'installation, à des réglages,
de l'entretien ou des réparations.
L'installation de ce produit doit être
effectuée par un réparateur qualifié.
Toute modification de ce produit peut
être extrêmement dangereuse et
entraîner des blessures ou dommages
matériels.
641415.30X
641416.30X
641432.30X
641435.30X
641515.30X
641516.30X
641535.30X
641715.30X
641716.30X
641732.30X
641735.30X
641815.30X
641815C35X
1
RECORD THIS UNIT INFORMATION
FOR FUTURE REFERENCE:
Model Number
Serial Number
ADB Number
ADB Serial Number
Date Purchased
Indoor Temperature
Sensor
N/A
N/A
Optional 3106486.XXX
Optional 3106486.XXX
N/A
N/A
Optional 3311931.XXX
Optional 3311931.XXX
N/A
N/A
N/A
N/A
Optional 3106486.XXX
N/A
N/A
Optional 3311931.XXX
N/A
N/A
Optional 3106486.XXX
Optional 3106486.XXX
Optional 3311931.XXX
Optional 3311931.XXX
N/A
N/A
MODELS
641815.80X
641915C85X
651815C35X
641815C85X
641916.30X
651815.80X
641816.30X
641916C35X
651815C85X
641816C35X
641916.80X
651816.30X
641816.80X
641916C85X
651816C35X
641816C85X
641932.30X
651816.80X
641835.30X
641935.30X
651816C85X
641835C35X
641935C35X
651915.30X
641835.80X
641935.80X
651916.30X
641835C85X
641935C85X
651916C35X
641915.30X
651515.30X
651916.80X
641915C35X
651516.30X
651916C85X
641915.80X
651815.30X

Advertisement

Table of Contents
loading

Summary of Contents for Dometic 641415.30 series

  • Page 1: Installation Instructions

    641732.30X 641835C85X 641935C85X 651916C35X 641735.30X 641915.30X 651515.30X 651916.80X 641815.30X 641915C35X 651516.30X 651916C85X REVISION A 641815C35X 641915.80X 651815.30X Form No. 3312500.030 09/16 (French 3312709.037_A) Read these instructions carefully. These ©2016 Dometic Corporation instructions MUST stay with this product. LaGrange, IN 46761...
  • Page 2: Important Safety Instructions

    For a more permanent solution to a high heat gain, ac- cessories like Dometic outdoor patio and window awnings will reduce heat gain by removing the direct exposure to CAUTION, used with the safe- the sun.
  • Page 3: Specifications

    For wire length over 24 ft., consult the National Electric Code for proper sizing. ** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications. When sizing the generator, the total power usage of your recreational vehicle must be considered.
  • Page 4 (± 1/8") Opening tion. Front 2. Dometic Corporation will not be liable for any damages or injury incurred due to failure in fol- lowing these instructions. 4" 3. Installation MUST comply with the National Elec- 4"...
  • Page 5: Roof Preparation

    C. Roof Preparation D. Wiring Requirements 1. Opening Requirements - Before preparing the 1. Route a copper, with ground, 120 VAC supply ceiling opening, the type of system options must wire from the time delay fuse or circuit breaker be decided upon. Read all of the following instruc- box to the roof opening.
  • Page 6: Choosing Thermostat Location

    Important: a. Locate the thermostat 54" above the floor. When more than one unit is being in- b. Install the thermostat on a partition, not on an stalled (additional zones) with the CCC and CCC 2 outside wall. thermostat, an additional 4 conductor communica- c.
  • Page 7 FIG. 6 FIG. 8 CCC Thermostat CCC 2 Thermostat Insert Screwdriver Under Tab c. Insert the control cable through the hole in Disengage Tab the base plate and mount the plate to the wall with the two (2) screws provided. Insert the 4 conductor communication d.
  • Page 8 e. Make the following connections to the ther- FIG. 10 mostat. See FIG 11. • Red/white wire to the +7.5 terminal • Green wire to the "GND" terminal • Yellow wire to "COOL" terminal • Tan wire to the "FAN" terminal •...
  • Page 9: Installing The Unit

    G. Placing The Unit On The Roof 2. Remove air distribution box and mounting hard- ware from the air distribution box kit carton. 1. Remove the unit from the carton and discard 3. Remove wire tie holding center of rear aluminum carton.
  • Page 10 SHOCK HAZARD. This product is equipped PROPERTY DAMAGE HAZARD. If bolts are with a 2 wire plus ground system for protec- left loose there may not be an adequate roof tion against shock hazard. Make sure that the seal or if over tightened, damage may occur unit is wired into a properly grounded 120 VAC to the unit base or ceiling template.
  • Page 11: Air Distribution Box Installation

    I. Wiring The System (Low Voltage Connec- c. Connect red/white wire protruding from the units return air opening to the seven wire tions) cable thermostat +7.5 terminal. 1. CCC, CCC 2 & Digital Thermostat d. Connect the green wire protruding from the units return air opening to the seven wire ca- ble thermostat “GND”...
  • Page 12 2. Push up on the ADB at the locations indicated by 5. Filter installation. Slide filters into slots in air dis- the paper labels to engage the snap locks. There tribution box. The outward curved side of the filter will be a quiet click heard when each latch en- handle faces the ceiling.
  • Page 13: Off Position

    CCC Dip Switch Selection e. Heat Pump - On heat pump models the #7 dip switch is in the "ON" position from the factory. a. Each CCC thermostat can have up to 4 zones. Non heat pump models leave in the "OFF" When only one unit is installed it becomes position.
  • Page 14: Service-Unit Does Not Operate

    L. Furnace/Aqua Temperature Differential D. Frost Formation On Cooling Coil Setting (CCC 2 Only) 1. Frost on a small portion of the coil is not unusual. Under certain conditions, ice may form on the This system can be configured to operate using an ON/OFF evaporator coil.
  • Page 15: Wiring Diagram

    FIG. 25 (OPTIONAL) WIRING DIAGRAM 6414 Series...
  • Page 16 WIRING DIAGRAM 6415 Series 6417 Series 6418 Series...
  • Page 17 WIRING DIAGRAM 641915 & 641916 Series 641932 & 641935 Series 6515 Series...
  • Page 18 WIRING DIAGRAM 6518 Series 6519 Series...

Table of Contents