Page 1
1120 North Main Street 3105935.XXX 3314082.XXX Elkhart, IN 46514 SERVICE CENTER & DEALER LOCATION Please visit: www.eDometic.com This Unit is designed for OEM installation. All initial installations must be approved by Dometic Corporation MODEL 640312.30X 640315C35X 640312C35X 640315.80X INSTALLATION INSTRUCTIONS 640312.80X 640315.83X...
Recreational Vehicle (RV) during the time it is manufactured. This unit can be installed by one person with brief help from additional personnel. Use the following procedure to ensure a properly installed, and properly functioning product. Dometic Corporation reserves the right to modify appearances and specifications without notice. TABLE OF CONTENTS INTRODUCTION ..................................2 DOCUMENT SYMBOLS...............................2...
● This product MUST be [installed / serviced] by a qualified service technician. ● Do NOT modify this product in any way. Modifica- tion can be extremely hazardous. ● Do NOT add any devices or accessories to this product except those specifically authorized in writing by Dometic Corporation.
For wire length over 24 ft., consult the National Electrical Code for proper sizing. ** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications. When sizing the generator, the total power usage of your RV must be considered.
INSTALLATION PROCEDURE Choosing Proper Location For Unit FIG. 2 Dimensions Are Nominal This unit is specifically designed for installation on the roof 17″ of a recreational vehicle (RV). When determining your 3/4″ cooling requirements, the following should be considered: 17″ ● Size of RV; ● Window area (increases heat gain); 1-1/2″...
6. Air Distribution System Installation 1. Make sure ductwork will NOT bend or collapse during and after installation, a. Dometic Corporation recommends the basic and that it is correctly insulated and sealed. configuration shown on page 7, for installing Otherwise, damage to roof structure and ceiling this system.
INSTALLATION PROCEDURE FIG. 5 Duct Size And Requirements For 3105007.XXX And 3105935.XXX Return Air Grille Register Required Register Required Short Duct Run Minimum Registers 1/3 Total Duct Length 4 Min. - 8 Max. (Per Unit) Total Outlet Air Area 14 Sq. In. Free Minimum 21.0 Sq.
INSTALLATION PROCEDURE Choosing Thermostat Location FIG. 7 1. If the system is to be used WITHOUT an indoor Pin 1 temperature sensor, the proper location of the CCC 2 thermostat is very important to ensure that it will provide a comfortable RV tempera- RJ-11-6C4P Connector ture.
INSTALLATION PROCEDURE Installing The LCD SZ System FIG. 9 CCC 2 Thermostat W ire colors listed for the communication ca- ble (3-conductor cable) match the wire colors in the unit wire harness and the wire harness at the LCD SZ electronic control box. Avail- able wire colors may vary.
INSTALLATION PROCEDURE Placing Unit On Roof FIG. 13 Center Unit From Below 1. R emove the unit from the carton and discard carton. 2. LIFTING HAZARD. Use proper lifting technique and control when lifting product. Failure to obey this caution could result in injury. Place the unit on the roof.
Page 11
INSTALLATION PROCEDURE 6. Installation Of Divider Plate FIG. 15 Control a. Measure the ceiling to roof thickness: Cables ● If distance is 2.0″ - 3-3/4″, remove perfo- rated tab from divider plate. See (FIG. 17). ● If distance is 3-3/4″ - 5-1/2″, remove no Furnace tabs. Wires b.
INSTALLATION PROCEDURE d. With slight pressure push the divider plate FIG. 20 against the double sided tape on the ceiling template. Freeze Control e. Locate the 1/8″ x 7″ x 18″ self-adhesive in- Sensor sulation supplied with the return air grille kit. Remove the backing paper from the insula- tion and carefully stick onto the ceiling tem- plate divider panel.
INSTALLATION PROCEDURE d. Terminate the 4 conductor communication FIG. 22 cable(s) protruding into the roof opening. The cable(s) must be terminated with a tele- phone RJ-11-6C4P connector. Refer to the crimp tool manufacturer for crimping instruc- tions. Switches R J-11-6C4P connectors MUST be in- stalled as shown in (FIG.
INSTALLATION PROCEDURE System Reset & Checkout g. Dehumidify - Dehumidify is not used on this unit. Leave in the “OFF” position. 1. System Reset h. Gen start selection - Leave in the “OFF” After setting the dip switches in the electronic position.
For a more permanent solution to high heat gain, acces- sories like Dometic outdoor patio and window awnings will reduce heat gain by removing the direct sun. They also add a nice area to enjoy company during the cool of the evening.