TECHNICAL DATA
(****)
MODELS
General data
Electricity supply
Refrigerant gas
Fuse
Minimum cable section
Size and clearance
Indoor unit net weight
Outdoor unit net weight
Connecting pipes
Refrigerant pipe size
Pipe tightening torque
Quantity of refrigerant per metre of pipe (over 5 m)
Refrigerant charge
Operating limits
Cooling (Max ; Min)
Heating (Max ; Min)
(*)
See the rating plate for the electricity supply.
(**) Theappliance may be supplied with refrigerant gas R22 in countries where the use
of refrigerant gas R410a is not compulsory.
(***) See the rating plate for the refrigerant charge.
(****) The models correspond respectively to the following De Longhi product names:
DECON28, DECON35, DECON52, DECON73, DECON81
GENERAL INFORMATION
9K
12K
18K
230~50 (*)
R410 A (**)
10
10
16
1,0
1,0
1,5
L
845
845
940
H
275
275
298
P
180
180
200
150
A
150
B
2500
C
150
D
E
300
L
848
848
913
P
320
320
378
H
540
592
680
C
300
D
500
F
300
E
2000
10
10
13
40
41
46
Liquid
6,0 - 1/4 6,0 - 1/4 6,0 - 1/4
Gas
9.52-3/8
12-1/2
12-1/2
Liquid
20
20
20
Gas
35
55
55
20
20
20
A
10
10
10
(max)
B
15
20
25
(max)
C
10
10
10
(max)
(***)
Internal part bulb
32 ; 21
27 ; 20
24K
28K
V~Hz
20
20
A
2,5
2,5
mm
1178
1178
mm
326
326
mm
253
253
mm
mm
mm
mm
mm
mm
980
980
mm
427
427
mm
790
790
mm
mm
mm
mm
mm
17.5
17.5
kg
72
68
kg
6,0 - 1/4
inch
6,0 - 1/4
16-5/8
16-5/8
inch
20
20
m
N
65
65
Nm
50
50
g/m
10
10
m
30
30
m
10
10
m
g.
External part bulb
°C
43 ; 21
°C
24 ; -5