• Use this appliance only as described in this instruction manual.
As with any electrical appliance, the instructions aim to cover as many situations as possible.
Caution and common sense should be used when operating and installing this air conditioner.
• This appliance has been manufactured to cool and dehumidify domestic environments and
must not be used for other purposes.
• It is dangerous to alter or modify the unit's characteristics in any way.
• The appliance must be installed in accordance with the relevant national legislation.
• Should repairs be necessary, contact the nearest authorized Repair Service Center. Unautho-
rized servicing can be dangerous.
• The appliance is not intended for use by persons (including children) with reduced physical, sen-
sory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
• In the case that the power cord becomes damaged, this must be repaired only by specialized per-
sonnel authorized by the manufacturer in order to protect against fire.
• Always ensure the appliance is plugged into a grounded 3-prong outlet. If you have any doubts
check with a qualified electrician.
• We strongly discourage the use of an extension cord due to potential safety hazards. For tem-
porary situations, use only CSA certified and UL listed 3-prong grounded extension cord,
attachment plug and connector, rated 15A, 125V
• Before cleaning or maintenance operations, always unplug the unit from the outlet.
• Do not pull on or place strain on the power cord when moving the appliance.
• The appliance should not be installed where the atmosphere may contain combustible gases,
oil or sulphur, or near heat sources.
• Do not rest hot or heavy objects on the appliance.
• Clean the filters at least once a week.
• Avoid using heaters near the unit.
• The unit should be transported in a vertical position. If this is not possible secure the unit at an
angle, do not lie it horizontally.
• Before transporting the unit, drain the unit. After transportation, wait at least 6 hours before switching the unit on.
• The packaging materials can be recycled. You are therefore recommended to place them in
the special containers for differentiated waste collection.
• This appliance is fitted with a special safety device. When the compressor switches off, this
device prevents it from switching on again for at least 3 minutes.
• WARNING: Changes or modifications not expressly approved by the party responsible for com-
pliance could void the user's authority to operate the equipment.
.
THIS PRODUCT IS FOR HOUSEHOLD ONLY
DESCRIPTION
1 air outlet grille
2 control panel
3 castor wheels
4 handles
5 filter
6 air intake grille
7 air exhaust hose housing
8 drainage hose
4

Important safeguards

SAVE THESE INSTRUCTIONS
9 power cable
10 wall flange
11 air exhaust hose
12 window outlet
13 castor locks
14 remote control
15 window bracket with locking pins

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pinguino PAC CT110 and is the answer not in the manual?

Questions and answers

Summary of Contents for DeLonghi Pinguino PAC CT110

  • Page 1: Important Safeguards

    Important safeguards • Use this appliance only as described in this instruction manual. As with any electrical appliance, the instructions aim to cover as many situations as possible. Caution and common sense should be used when operating and installing this air conditioner. •...
  • Page 2: Setting Up

    Setting up your portable air conditioner TO AVOID DAMAGE TO THE UNIT: NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. (After the unit has been on its side, oil needs to return to the compressor to ensure proper function.
  • Page 3: Semi-Permanent Installation

    Semi-permanent installation • Fit the wall flange (10) into the hole. SEMI-PERMANENT INSTALLATION • Fit the air exhaust hose (11) in the rele- If required, your appliance can also be vant housing located on the rear side of installed semi-permanently (Fig. E). the appliance.
  • Page 4: Control Panel

    Control panel THE CONTROL PANEL DESCRIPTION OF THE CONTROL PANEL A ON/STAND-BY button B MODE selection button: Air conditioning, dehumidifying, fan. C Fan speed selection button (HIGH/MED/LOW/AUTO) D Timer button Programmed operation increase temperature/time button Programmed operation decrease temperature/time button G Display Displays the temperature values set and the programmed operating time H Timer in operation indicator light I/L/M/N Fan speed lights and AUTO lights...
  • Page 5: Operation

    Operation TURNING THE APPLIANCE ON Plug into an outlet. Two lines appear on the display indicating that the appliance is in stand- Press the ON/STAND-BY button (A). When turned on, the air conditioner starts operating in the same mode as when it was turned off. Press the MODE button (B) until the light corresponding to the desired mode lights up: Light (Q)
  • Page 6: Self-Diagnosis

    Self-diagnosis SELF-DIAGNOSIS The appliance has a self diagnosis system to identify a number of malfunctions. IF ... IS DISPLAYED ...WHAT SHOULD YOU DO? The appliance is fitted with a frost protection device to avoid excessive formation of ice on internal components. The appliance starts up again automatically when the defrosting process is com- LOW TEMPERATURE (frost prevention)
  • Page 7: Using The Remote Control

    Using the remote control MODELS WITH REMOTE CONTROL • Point the remote control at the receiver on the air conditioner. The remote control MAX 23 ft must be no more than 23 ft (7 metres) MAX 7 metres away from the appliance (without obsta- cles between the remote control and the receiver) •...
  • Page 8: Fan Mode Only

    Using the remote control TURNING THE APPLIANCE ON Plug into the outlet. Press the ON/STAND-BY button (17) (when turned on, the air conditioner starts operating in the same mode as when it was turned off). Press the MODE button (18) to select the required mode: AIR CONDITIONING ( DEHUMIDIFYING ( FAN ONLY (...
  • Page 9 Using the remote control • At the end of the set time the appliance switches off automatically. • To cancel the timer programming, press the timer button (19) again. The appliance emits a beep and both displays reset to display the settings prior to activation of the timer. How to program delayed start up •...
  • Page 10 Tips • Never rest objects of any kind on the air To ensure optimal performance from your conditioner; portable air conditioner, follow these recom- • Never obstruct the air intake (6) or outlet mendations: (1) grilles; • close the windows and doors in the room to be air conditioned.
  • Page 11: Cleaning The Surface Of The Unit

    Cleaning Before cleaning or maintenance, turn the START OF SEASON CHECKS appliance off by pressing the ON/STAND-BY Make sure the power cable and plug are button then always unplug the appliance undamaged and the outlet is in good condi- from the outlet. tion.
  • Page 12: Troubleshooting

    Troubleshooting NOTE: NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. (After the unit has been on its side, oil needs to return to the compressor to ensure proper function. With- out allowing the unit this time (6-24 hours) The unit may function for only a short time, and then the compressor will break down from lack of oil.) TROUBLESHOOTING...
  • Page 13: Limit Conditions

    Technical specifications TECHNICAL SPECIFICATION LIMIT CONDITIONS Power supply voltage see rating label Max. absorbed power Room temperature for during air conditioning “ air conditioning 64 ÷ 95°F (18° ÷ 35°C) Refrigerant “ Cooling capacity “ Transport, filling, cleaning, recovery and dis- posal of refrigerant should be performed by a technical service centre appointed by the manufacturer only.
  • Page 14: Limited Warranty

    Please contact our toll free customer service call center at Monday – Friday 8:30am – 5:00pm ET or log onto our website at www.delonghiusa.com. CANADA Residents: 1-888-335-6644 Please contact our toll free hotline at or log onto our website at www.delonghi.com. Other countries: Please visit: www.delonghi.com.