Fault - Water Flows From Hot Tap But Has Reduced Flow From Cold; Fault - Reduced Flow From Both Hot And Cold Taps; Fault - Reduced Flow From Either Taps; Fault - Water Heater Pressure Relief Valve Venting Water - Bailey Caravan Owner's Manual

Table of Contents

Advertisement

5
General
5.4.4

FAULT - Water flows from hot tap but has reduced flow from cold

Cause
Cold water pipe kinked preventing flow
Blockage in cold pipe line
Cold tap not connected
Cold tap failed or blocked
If a Carver Crystal water service unit is
fitted the cartridge is exhausted

FAULT - Reduced flow from both hot and cold taps

5.4.5
Cause
Battery condition low causing pump to run
slowly
If new taps have been fitted they may be
restricting flow
Pump needs servicing
Partially blocked pump filter or in-line
filter, if fitted
Pump outlet pipe kinked restricting flow
Water leak
5.4.6

FAULT - Reduced flow from either taps

Cause
'Y' connector(s) fitted incorrectly
Pipe kinking restricting flow
Bore size difference in taps
5.4.7

FAULT - Water Heater pressure relief valve venting water

Cause
Pressurised water system pump switching
pressure too high
Switched tap water system pump flow rate
is greater than tap flow rate capacity
5-10
Cure
Check and re-route if necessary
Disconnect pipes after 1st Y connector and
check up to tap
Refer to installation instructions
Disconnect and inspect
Replace cartridge
Cure
Check battery state of charge refer to electrical
supply note
Disconnect and check that they have at least Ø
(6.3mm) bore
Refer to pump servicing instructions
Dismantle and clean if necessary
Check and re-route if necessary
Check all water connections
Cure
Refer to installation instructions
Check and re-route if necessary
Use taps of equal bore size
Cure
Refer to water supply note
Refer to water supply note