Ortech TR-100 User Manual page 29

Digital grill control
Table of Contents

Advertisement

Unexpected
Temperature is
Displayed
Grill Temperature
Displayed is Different
Than Dome
Thermometer
Displayed
Temperature
is Flashing
Display Always
Reads 0 Degrees
Auger Idle Fuel Feed Rate is too high.
Adjust Smoke Control switch (increase the "P" setting) to
decrease Idle Fuel Feed Rate.
Auger Idle Fuel Feed Rate is too low.
Adjust Smoke Control switch (decrease the "P" setting) to
increase Idle Fuel Feed Rate.
Grill lid is open.
Close grill lid. Grill is designed to operate with grill lid
closed.
Temperature detector is defective.
Replace temperature detector.
Control is defective.
Contact Ortech Controls customer service.
This is normal.
The displayed temperature is the precise temperature at
the temperature detector. The dome thermometer is
located in a different position inside the grill.
Low grill temperature.
This is not an error condition and does not affect the
operation of the grill. The flashing display is designed to
alert the operator that there is some risk of the fire going
out.
Temperature detector wire leads are shorted.
Check connection at control terminal J1. Fully open contacts
by turning set screw counter clockwise. Reinsert wires and
tighten contacts by turning set screw clockwise.
Check the insulation for shorts throughout the wire run from
detector to control terminal J1.
Temperature detector is defective.
Replace temperature detector.
Control is defective.
Contact Ortech Controls customer service.
26