Understanding Idle Fuel Feed Rate And Smoke Settings - Ortech TR-100 User Manual

Digital grill control
Table of Contents

Advertisement

Understanding Idle Fuel Feed Rate and Smoke Settings

Smoke Control
Switch
"P" Settings
Dual Function
The Smoke Control switch sets the fuel feed rate (the
amount of fuel delivered in a given period of time) when the
grill is operating in Smoke Mode and when the grill is idling
in Cook Mode.
During cook idle or smoke mode, the auger turns on,
delivers fuel for 15 seconds, then turns off. The off time is
set by the Smoke Control switch.
The fuel feed rate setting is displayed momentarily
whenever the Cook Control switch is set to the Smoke
position. It is also displayed whenever the Smoke Control
switch is adjusted. The setting is designated with the letter
"P" and a number. The greater the "P" setting number the
greater the auger off time.
Setting
Auger On
P 0
15 seconds
P 1
15
P 2
15
P 3
15
P 4
15
P 5
15
P 6
15
P 7
15
P 8
15
P 9
15
P10
15
P11
15
P12
15
P13
15
P14
15
P15
15
The selected "P" setting controls both the Smoke Mode fuel
feed rate and the Cook Mode Idle Fuel Feed Rate. They are
one and the same.
For example, if "P3" is selected using the Smoke Control
switch, the auger delivers fuel for 15 seconds, turns off for
75 seconds, and repeats in Smoke Mode. It also delivers
fuel for 15 seconds, turns off for 75 seconds and repeats
while idling at or above the selected set temperature in Cook
Mode.
17
Auger Off
45 seconds
55
65
75
85
95
105
115
125
135
140
145
150
155
160
165

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents