Digital grill control
Table of Contents

Advertisement

Grill Temperature
at the 180 Degree
Cook Setting is too
High
Grill Temperature
at the High Cook
Setting is too Low
Auger Idle Fuel Feed Rate is too high.
Adjust Smoke Control switch (increase the "P" setting) to
decrease Idle Fuel Feed Rate.
Temperature detector is defective.
Replace temperature detector.
Control is defective.
Contact Ortech Controls customer service.
At the High temperature setting, the auger runs continually
until the grill temperature reaches 450 degrees.
Grill lid is open.
Close grill lid. Grill is designed to operate with grill lid
closed.
Insufficient amount of fuel in fire pot.
Clear auger if jammed.
Tighten auger connection to auger motor shaft if slipping.
Replace auger and/or auger motor if defective.
Damp fuel source.
Replace damp fuel with good dry fuel.
Adverse operating conditions.
Shield grill from cold wind and/or rain.
Grill may not be able to attain 450 degrees in an extremely
cold operating environment.
Temperature detector is defective.
Replace temperature detector.
Control is defective.
Contact Ortech Controls customer service.